YaBeSH Engineering and Technology Library

    • Journals
    • PaperQuest
    • YSE Standards
    • YaBeSH
    • Login
    View Item 
    •   YE&T Library
    • ASME
    • Journal of Turbomachinery
    • View Item
    •   YE&T Library
    • ASME
    • Journal of Turbomachinery
    • View Item
    • All Fields
    • Source Title
    • Year
    • Publisher
    • Title
    • Subject
    • Author
    • DOI
    • ISBN
    Advanced Search
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Archive

    Evaluating the Use of Leaned Stator Vanes to Produce a Non-Uniform Flow Distribution Across the Inlet Span of a Mixed Flow Turbine Rotor

    Source: Journal of Turbomachinery:;2020:;volume( 142 ):;issue: 012::page 0121001-1
    Author:
    Morrison, Richard
    ,
    Spence, Stephen
    ,
    Kim, Sung In
    ,
    Leonard, Thomas
    ,
    Starke, Andre
    DOI: 10.1115/1.4047811
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: Current trends in the automotive industry have placed an increased emphasis on downsized turbocharged engines for passenger vehicles. The turbocharger is increasingly relied upon to improve power output across a wide range of engine operating conditions, placing a greater emphasis on turbocharger off-design performance. An off-design condition of significant importance is performance at low turbine velocity ratios, since it is relevant to engine transient response and also to efficient energy extraction from pressure pulses in the unsteady exhaust flow. An increased focus has been placed on equipping turbochargers with mixed flow turbine rotors instead of conventional radial flow turbine rotors to improve off-design performance and to reduce rotor inertia.A recognized feature of a mixed flow turbine is the spanwise variation of flow conditions across the blade leading edge. This is a consequence of the reduction in leading edge radius from shroud to hub, coupled with the increasing tangential velocity of the flow due to conserved angular momentum as the radius decreases. The result is increasingly positive incidence toward the hub side of the leading edge. The resulting region of highly positive incidence at the hub produces separation from the suction surface and generates significant loss within the rotor passage.The aim of this study was to determine if the losses in a mixed flow turbine (MFT) could be reduced by the use of leaned stator vanes, which deliberately created a significant spanwise variation of flow angle between hub and shroud at rotor inlet, to reduce the positive incidence at the hub. The turbine performance with a series of leaned vanes was compared against that of a straight vane using a validated computational fluid dynamics (CFD) model. It was found that increasing vane lean improved turbine performance at all operating points considered. An increase of 3.2 percentage points in stage total-to-static efficiency was achieved at a key off-design operating point.Experimental testing of a set of leaned vanes and the baseline vanes confirmed the advantage of the leaned vanes at all operating points, with an increase in measured efficiency of 2.6 percentage points at the key off-design condition. Unsteady CFD models confirmed the same level of improvement at this operating point.The CFD and experimental results confirmed that the losses in an MFT can be reduced by the use of leaned stator vanes to shape the flow at rotor inlet.
    • Download: (3.533Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      Evaluating the Use of Leaned Stator Vanes to Produce a Non-Uniform Flow Distribution Across the Inlet Span of a Mixed Flow Turbine Rotor

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4274713
    Collections
    • Journal of Turbomachinery

    Show full item record

    contributor authorMorrison, Richard
    contributor authorSpence, Stephen
    contributor authorKim, Sung In
    contributor authorLeonard, Thomas
    contributor authorStarke, Andre
    date accessioned2022-02-04T22:00:59Z
    date available2022-02-04T22:00:59Z
    date copyright10/19/2020 12:00:00 AM
    date issued2020
    identifier issn0889-504X
    identifier othergtp_142_10_101009.pdf
    identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4274713
    description abstractCurrent trends in the automotive industry have placed an increased emphasis on downsized turbocharged engines for passenger vehicles. The turbocharger is increasingly relied upon to improve power output across a wide range of engine operating conditions, placing a greater emphasis on turbocharger off-design performance. An off-design condition of significant importance is performance at low turbine velocity ratios, since it is relevant to engine transient response and also to efficient energy extraction from pressure pulses in the unsteady exhaust flow. An increased focus has been placed on equipping turbochargers with mixed flow turbine rotors instead of conventional radial flow turbine rotors to improve off-design performance and to reduce rotor inertia.A recognized feature of a mixed flow turbine is the spanwise variation of flow conditions across the blade leading edge. This is a consequence of the reduction in leading edge radius from shroud to hub, coupled with the increasing tangential velocity of the flow due to conserved angular momentum as the radius decreases. The result is increasingly positive incidence toward the hub side of the leading edge. The resulting region of highly positive incidence at the hub produces separation from the suction surface and generates significant loss within the rotor passage.The aim of this study was to determine if the losses in a mixed flow turbine (MFT) could be reduced by the use of leaned stator vanes, which deliberately created a significant spanwise variation of flow angle between hub and shroud at rotor inlet, to reduce the positive incidence at the hub. The turbine performance with a series of leaned vanes was compared against that of a straight vane using a validated computational fluid dynamics (CFD) model. It was found that increasing vane lean improved turbine performance at all operating points considered. An increase of 3.2 percentage points in stage total-to-static efficiency was achieved at a key off-design operating point.Experimental testing of a set of leaned vanes and the baseline vanes confirmed the advantage of the leaned vanes at all operating points, with an increase in measured efficiency of 2.6 percentage points at the key off-design condition. Unsteady CFD models confirmed the same level of improvement at this operating point.The CFD and experimental results confirmed that the losses in an MFT can be reduced by the use of leaned stator vanes to shape the flow at rotor inlet.
    publisherThe American Society of Mechanical Engineers (ASME)
    titleEvaluating the Use of Leaned Stator Vanes to Produce a Non-Uniform Flow Distribution Across the Inlet Span of a Mixed Flow Turbine Rotor
    typeJournal Paper
    journal volume142
    journal issue12
    journal titleJournal of Turbomachinery
    identifier doi10.1115/1.4047811
    journal fristpage0121001-1
    journal lastpage0121001-9
    page9
    treeJournal of Turbomachinery:;2020:;volume( 142 ):;issue: 012
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian