Show simple item record

contributor authorde Klerk, Gary
contributor authorRousseau, Pieter
contributor authorJestin, Louis
date accessioned2022-02-04T14:48:52Z
date available2022-02-04T14:48:52Z
date copyright2020/03/13/
date issued2020
identifier issn1948-5085
identifier othertsea_12_5_051015.pdf
identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4274433
description abstractDue to the penetration of variable renewable energy (VRE) sources into electricity supply grids, conventional coal fired power plants need to operate with greater flexibility while remaining reliable and conserving the lifetime of components. Thick-sectioned components are prone to thermal fatigue cracking as a result of through-wall temperature gradients. These temperature gradients can be significantly amplified during quenching when components at high temperature are unintentionally exposed to colder liquid or steam. Such quench events are known to occur during two-shift operation of a large once-through coal fired tower type boiler. The purpose of this study is to develop and demonstrate a model that can be used to determine the root cause and magnitude of quenching. The model is developed using the least level of detail to make it readily usable by power plant engineers. Two different approaches are used. A liquid tracking model (LTM) was developed from first principles that approximates the liquid level in the superheater as a function of time. The model is presented and verified by comparison with real-plant data. The second approach was to configure a model in flownex, which is a commercially available software package. The LTM model with eight control volumes provided better steam temperature results and was able to simulate the correct superheater pressure behavior without solving the momentum equation. The models proved that a separator overflow was the cause of quenching for this particular case study.
publisherThe American Society of Mechanical Engineers (ASME)
titleA Dynamic Modeling Methodology to Estimate the Magnitude of Unwanted Liquid Flows in High Temperature Boiler Components
typeJournal Paper
journal volume12
journal issue5
journal titleJournal of Thermal Science and Engineering Applications
identifier doi10.1115/1.4046517
page51015
treeJournal of Thermal Science and Engineering Applications:;2020:;volume( 012 ):;issue: 005
contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record