Show simple item record

contributor authorKumar, Rajneesh
contributor authorGoel, Varun
contributor authorKumar, Anoop
date accessioned2022-02-04T14:43:59Z
date available2022-02-04T14:43:59Z
date copyright2020/02/20/
date issued2020
identifier issn0022-1481
identifier otherht_142_04_041901.pdf
identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4274258
description abstractThe plate fin heat exchangers usually have either rectangular or triangular shaped flow passage. In comparison to triangular flow passage, rectangular flow passage gives comparatively higher heat transfer at the cost of higher pumping power. In the present investigation, flow passage is modified by rounding the corner of triangular passage to investigate the heat and flow characteristics of air flowing through it. Comparison of performance between modified and rectangular flow passage has also been presented and discussed. The radius of curvature of the rounded corner has been kept constant with value of 0.49 times duct height (H). The dimple was also fabricated at the inner side of the flow passage and arranged in rectangular array. Distance between them was defined by two different dimensionless parameters, relative transverse width (x/h), and relative streamwise length (z/h), whereas, dimensionless height of the protrusion is defined by relative dimple height (h/D). Noticeable increment in both heat transfer and friction factor has been observed by modifying the duct corners and 2.98 times increment in Nusselt number resulted due to dimples in modified duct for h/D, x/h, and y/h value of 0.44, 10, and 10, respectively, in comparison to smooth duct at Reynolds number of 19,500. For similar combination of roughness parameters, highest frictional penalty was estimated with value of 4.46 times that of the smooth duct at Reynolds number of 4400. Additionally, the comparative assessment of heat transfer enhancement (Nuenh), frictional penalty (fpenalty), and thermohydraulic performance index (THPi) has also been carried out to understand the suitability of round cornered duct. In comparison to protruded rectangular duct, 28% higher THPi is obtained in modified duct under similar conditions.
publisherThe American Society of Mechanical Engineers (ASME)
titleA Note on the Comparative Analysis Between Rectangular and Modified Duct Heat Exchanger
typeJournal Paper
journal volume142
journal issue4
journal titleJournal of Heat Transfer
identifier doi10.1115/1.4045755
page41901
treeJournal of Heat Transfer:;2020:;volume( 142 ):;issue: 004
contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record