    A Modified Directional Flame Thermometer: Development, Calibration, and Uncertainty Quantification

    Source: Journal of Verification, Validation and Uncertainty Quantification:;2020:;volume( 005 ):;issue: 001
    Author:
    Cabrera, J. M.
    ,
    Moser, R. D.
    ,
    Ezekoye, O. A.
    DOI: 10.1115/1.4046657
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: The directional flame thermometer (DFT) is a robust device used to measure heat fluxes in harsh environments such as fire scenarios but is large when compared to other standard heat flux measurement devices. To better understand the uncertainties associated with heat flux measurements in these environments, a Bayesian framework is utilized to propagate uncertainties of both known and unknown parameters describing the thermal model of a modified, smaller DFT. Construction of the modified DFT is described along with a derivation of the thermal model used to predict the incident heat flux to its sensing surface. Parameters of the model are calibrated to data collected using a Schmidt–Boelter (SB) gauge with an accuracy of ±3% at incident heat fluxes of 5 kW/m2, 10 kW/m2, and 15 kW/m2. Markov Chain Monte Carlo simulations were used to obtain posterior distributions for the free parameters of the thermal model as well as the modeling uncertainty. The parameter calibration process produced values for the free parameters that were similar to those presented in the literature with relative uncertainties at 5 kW/m2, 10 kW/m2, and 15 kW/m2 of 17%, 9%, and 7%, respectively. The derived model produced root-mean-squared errors between the prediction and SB gauge output of 0.37, 0.77, and 1.13 kW/m2 for the 5, 10, and 15 kW/m2 cases, respectively, compared to 0.53, 1.12, and 1.66 kW/m2 for the energy storage method (ESM) described in ASTM E3057.
    • Download: (1.156Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      A Modified Directional Flame Thermometer: Development, Calibration, and Uncertainty Quantification

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4274007
    Collections
    • Journal of Verification, Validation and Uncertainty Quantification

    Show full item record

    contributor authorCabrera, J. M.
    contributor authorMoser, R. D.
    contributor authorEzekoye, O. A.
    date accessioned2022-02-04T14:36:15Z
    date available2022-02-04T14:36:15Z
    date copyright2020/03/30/
    date issued2020
    identifier issn2377-2158
    identifier othervvuq_005_01_011003.pdf
    identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4274007
    description abstractThe directional flame thermometer (DFT) is a robust device used to measure heat fluxes in harsh environments such as fire scenarios but is large when compared to other standard heat flux measurement devices. To better understand the uncertainties associated with heat flux measurements in these environments, a Bayesian framework is utilized to propagate uncertainties of both known and unknown parameters describing the thermal model of a modified, smaller DFT. Construction of the modified DFT is described along with a derivation of the thermal model used to predict the incident heat flux to its sensing surface. Parameters of the model are calibrated to data collected using a Schmidt–Boelter (SB) gauge with an accuracy of ±3% at incident heat fluxes of 5 kW/m2, 10 kW/m2, and 15 kW/m2. Markov Chain Monte Carlo simulations were used to obtain posterior distributions for the free parameters of the thermal model as well as the modeling uncertainty. The parameter calibration process produced values for the free parameters that were similar to those presented in the literature with relative uncertainties at 5 kW/m2, 10 kW/m2, and 15 kW/m2 of 17%, 9%, and 7%, respectively. The derived model produced root-mean-squared errors between the prediction and SB gauge output of 0.37, 0.77, and 1.13 kW/m2 for the 5, 10, and 15 kW/m2 cases, respectively, compared to 0.53, 1.12, and 1.66 kW/m2 for the energy storage method (ESM) described in ASTM E3057.
    publisherThe American Society of Mechanical Engineers (ASME)
    titleA Modified Directional Flame Thermometer: Development, Calibration, and Uncertainty Quantification
    typeJournal Paper
    journal volume5
    journal issue1
    journal titleJournal of Verification, Validation and Uncertainty Quantification
    identifier doi10.1115/1.4046657
    page11003
    treeJournal of Verification, Validation and Uncertainty Quantification:;2020:;volume( 005 ):;issue: 001
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian