Show simple item record

contributor authorBadida, Rohit
contributor authorGarcia-Lopez, Edgar
contributor authorSise, Claire
contributor authorMoore, Douglas C.
contributor authorCrisco, Joseph J.
date accessioned2022-02-04T14:14:39Z
date available2022-02-04T14:14:39Z
date copyright2020/03/27/
date issued2020
identifier issn0148-0731
identifier otherbio_142_06_064501.pdf
identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4273260
description abstractRobotic technology is increasingly used for sophisticated in vitro testing designed to understand the subtleties of joint biomechanics. Typically, the joint coordinate systems in these studies are established via palpation and digitization of anatomic landmarks. We are interested in wrist mechanics in which overlying soft tissues and indistinct bony features can introduce considerable variation in landmark localization, leading to descriptions of kinematics and kinetics that may not appropriately align with the bony anatomy. In the wrist, testing is often performed using either load or displacement control with standard material testers. However, these control modes either do not consider all six degrees-of-freedom (DOF) or reflect the nonlinear mechanical properties of the wrist joint. The development of an appropriate protocol to investigate complexities of wrist mechanics would potentially advance our understanding of normal, pathological, and artificial wrist function. In this study, we report a novel methodology for using CT imaging to generate anatomically aligned coordinate systems and a new methodology for robotic testing of wrist. The methodology is demonstrated with the testing of 9 intact cadaver specimens in 24 unique directions of wrist motion to a resultant torque of 2.0 N·m. The mean orientation of the major principal axis of range of motion (ROM) envelope was oriented 12.1 ± 2.7 deg toward ulnar flexion, which was significantly different (p < 0.001) from the anatomical flexion/extension axis. The largest wrist ROM was 98 ± 9.3 deg in the direction of ulnar flexion, 15 deg ulnar from pure flexion, consistent with previous studies [1,2]. Interestingly, the radial and ulnar components of the resultant torque were the most dominant across all directions of wrist motion. The results of this study showed that we can efficiently register anatomical coordinate systems from CT imaging space to robotic test space adaptable to any cadaveric joint experiments and demonstrated a combined load-position strategy for robotic testing of wrist.
publisherThe American Society of Mechanical Engineers (ASME)
titleAn Approach to Robotic Testing of the Wrist Using Three-Dimensional Imaging and a Hybrid Testing Methodology
typeJournal Paper
journal volume142
journal issue6
journal titleJournal of Biomechanical Engineering
identifier doi10.1115/1.4046050
page64501
treeJournal of Biomechanical Engineering:;2020:;volume( 142 ):;issue: 006
contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record