    Pull-Out Response of a Laboratory-Scale Energy Pile Subjected to Cooling Cycles

    Source: Journal of Geotechnical and Geoenvironmental Engineering:;2021:;Volume ( 147 ):;issue: 007::page 04021044-1
    Author:
    Rehab Elzeiny
    ,
    Muhannad T. Suleiman
    DOI: 10.1061/(ASCE)GT.1943-5606.0002534
    Publisher: ASCE
    Abstract: During winter, energy piles are subjected to cooling cycles due to the cyclic operation of the ground source heat pump (GSHP). The cyclic operation of the heat pump causes the energy pile to contract and expand axially and radially, affecting the soil–pile interaction. The effects of cooling cycles on the thermomechanical behavior of energy piles have not been fully investigated. A fully instrumented model concrete energy pile was installed in dry sand and subjected to cooling cycles. Cooling was achieved by circulating a heat exchange fluid with a target inlet temperature of 20°C lower than the initial temperature of the soil (ΔT=−20°C). Following the application of thermal loading, pull-out axial load tests were performed to evaluate the effects of cooling cycles on the load–displacement response of the energy pile. Baseline (room temperature), 5-cooling-cycle (5CC), and 100-cooling-cycle (100CC) tests were performed and summarized in this paper. During the thermal and mechanical load applications, temperature in the soil and the pile, axial strains, radial strains, and radial pressures at the soil–pile interface were measured. For the 1g scaled energy pile and test conditions (pile in dry sand subjected to cooling cycles with ΔT=−20°C), the peak pull-out loads decreased by 32% and 38% for the 5CC and 100CC tests, respectively.
    • Download: (3.539Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      Pull-Out Response of a Laboratory-Scale Energy Pile Subjected to Cooling Cycles

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4271520
    Collections
    • Journal of Geotechnical and Geoenvironmental Engineering

    Show full item record

    contributor authorRehab Elzeiny
    contributor authorMuhannad T. Suleiman
    date accessioned2022-02-01T00:29:41Z
    date available2022-02-01T00:29:41Z
    date issued7/1/2021
    identifier other%28ASCE%29GT.1943-5606.0002534.pdf
    identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4271520
    description abstractDuring winter, energy piles are subjected to cooling cycles due to the cyclic operation of the ground source heat pump (GSHP). The cyclic operation of the heat pump causes the energy pile to contract and expand axially and radially, affecting the soil–pile interaction. The effects of cooling cycles on the thermomechanical behavior of energy piles have not been fully investigated. A fully instrumented model concrete energy pile was installed in dry sand and subjected to cooling cycles. Cooling was achieved by circulating a heat exchange fluid with a target inlet temperature of 20°C lower than the initial temperature of the soil (ΔT=−20°C). Following the application of thermal loading, pull-out axial load tests were performed to evaluate the effects of cooling cycles on the load–displacement response of the energy pile. Baseline (room temperature), 5-cooling-cycle (5CC), and 100-cooling-cycle (100CC) tests were performed and summarized in this paper. During the thermal and mechanical load applications, temperature in the soil and the pile, axial strains, radial strains, and radial pressures at the soil–pile interface were measured. For the 1g scaled energy pile and test conditions (pile in dry sand subjected to cooling cycles with ΔT=−20°C), the peak pull-out loads decreased by 32% and 38% for the 5CC and 100CC tests, respectively.
    publisherASCE
    titlePull-Out Response of a Laboratory-Scale Energy Pile Subjected to Cooling Cycles
    typeJournal Paper
    journal volume147
    journal issue7
    journal titleJournal of Geotechnical and Geoenvironmental Engineering
    identifier doi10.1061/(ASCE)GT.1943-5606.0002534
    journal fristpage04021044-1
    journal lastpage04021044-14
    page14
    treeJournal of Geotechnical and Geoenvironmental Engineering:;2021:;Volume ( 147 ):;issue: 007
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian