    Post-Earthquake Fire Resistance of Circular Concrete-Filled Steel Tubular Columns

    Source: Journal of Structural Engineering:;2020:;Volume ( 146 ):;issue: 006
    Author:
    J. H. Wang
    ,
    S. Kunnath
    ,
    J. He
    ,
    Y. Xiao
    DOI: 10.1061/(ASCE)ST.1943-541X.0002632
    Publisher: ASCE
    Abstract: An experimental study was conducted to investigate the mechanical behavior and residual capacity of concrete-filled steel tubular (CFST) columns subjected to a post-earthquake fire. Nine circular cantilever CFST columns, including two control specimens, were tested to investigate their post-earthquake fire resistance time. The residual seismic behavior and load carrying capacity of an additional four columns were also studied following post-earthquake fire. All specimens were first subjected to a reversed cyclic or simulated earthquake loading (to induce initial seismic damage) and were then heated to obtain the fire resistance time or were subjected to additional cyclic reversed loading after a post-earthquake fire. The experimental results indicate that the CFST columns generally performed well after a post-earthquake fire. Specimens with high compressive strength concrete exhibited longer post-earthquake fire resistance times, whereas the increase in tube wall thickness only had a marginal effect on improving post-earthquake fire resistance. More importantly, the presence of residual lateral drift at the end of the earthquake loading had a much more significant effect on the post-earthquake fire performance than specimens without residual deformation. Finally, it is recommended that the failure criterion for fire loading should possibly take into consideration lateral deformation limits during fire testing.
    • Download: (1.664Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      Post-Earthquake Fire Resistance of Circular Concrete-Filled Steel Tubular Columns

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4266671
    Collections
    • Journal of Structural Engineering

    Show full item record

    contributor authorJ. H. Wang
    contributor authorS. Kunnath
    contributor authorJ. He
    contributor authorY. Xiao
    date accessioned2022-01-30T20:11:57Z
    date available2022-01-30T20:11:57Z
    date issued2020
    identifier other%28ASCE%29ST.1943-541X.0002632.pdf
    identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4266671
    description abstractAn experimental study was conducted to investigate the mechanical behavior and residual capacity of concrete-filled steel tubular (CFST) columns subjected to a post-earthquake fire. Nine circular cantilever CFST columns, including two control specimens, were tested to investigate their post-earthquake fire resistance time. The residual seismic behavior and load carrying capacity of an additional four columns were also studied following post-earthquake fire. All specimens were first subjected to a reversed cyclic or simulated earthquake loading (to induce initial seismic damage) and were then heated to obtain the fire resistance time or were subjected to additional cyclic reversed loading after a post-earthquake fire. The experimental results indicate that the CFST columns generally performed well after a post-earthquake fire. Specimens with high compressive strength concrete exhibited longer post-earthquake fire resistance times, whereas the increase in tube wall thickness only had a marginal effect on improving post-earthquake fire resistance. More importantly, the presence of residual lateral drift at the end of the earthquake loading had a much more significant effect on the post-earthquake fire performance than specimens without residual deformation. Finally, it is recommended that the failure criterion for fire loading should possibly take into consideration lateral deformation limits during fire testing.
    publisherASCE
    titlePost-Earthquake Fire Resistance of Circular Concrete-Filled Steel Tubular Columns
    typeJournal Paper
    journal volume146
    journal issue6
    journal titleJournal of Structural Engineering
    identifier doi10.1061/(ASCE)ST.1943-541X.0002632
    page04020105
    treeJournal of Structural Engineering:;2020:;Volume ( 146 ):;issue: 006
    contenttypeFulltext