    Archive

    Duration Analysis of Emergency Shutdown Incidents Regarding Hazardous Liquid Pipelines

    Source: Journal of Performance of Constructed Facilities:;2020:;Volume ( 034 ):;issue: 003
    Author:
    Alexander M. Hainen
    ,
    Kristopher B. Harbin
    ,
    Daniel Dye
    ,
    Jay K. Lindly
    DOI: 10.1061/(ASCE)CF.1943-5509.0001364
    Publisher: ASCE
    Abstract: Pipelines serve as critical infrastructure, and shutdowns of any duration can cause interruptions to sensitive supply chains. This paper develops a model using 789 incidents involving a hazardous liquid pipeline emergency shutdown with durations varying from a few minutes to months. A hazard-based duration analysis is used to understand the characteristics and mechanisms that influence how long a facility remained shut down. A parametric Weibull model with gamma heterogeneity is used to account for unobserved characteristics in the reported data. The insights gained from the duration analysis help to identify specific characteristics and areas that operators can address to decrease interruption durations. The findings address specific areas including response plans, incident locations, and maintenance programs where practices and policies could be implemented to reduce shutdown duration. Quantitative interpretation from marginal effects is presented, which can identify the improvement in duration rate for implemented changes. The model was applied to an historical incident in Marshall, Michigan, which confirmed the findings from the model.
    • Download: (1.576Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      Duration Analysis of Emergency Shutdown Incidents Regarding Hazardous Liquid Pipelines

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4264790
    Collections
    • Journal of Performance of Constructed Facilities

    Show full item record

    contributor authorAlexander M. Hainen
    contributor authorKristopher B. Harbin
    contributor authorDaniel Dye
    contributor authorJay K. Lindly
    date accessioned2022-01-30T19:10:27Z
    date available2022-01-30T19:10:27Z
    date issued2020
    identifier other%28ASCE%29CF.1943-5509.0001364.pdf
    identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4264790
    description abstractPipelines serve as critical infrastructure, and shutdowns of any duration can cause interruptions to sensitive supply chains. This paper develops a model using 789 incidents involving a hazardous liquid pipeline emergency shutdown with durations varying from a few minutes to months. A hazard-based duration analysis is used to understand the characteristics and mechanisms that influence how long a facility remained shut down. A parametric Weibull model with gamma heterogeneity is used to account for unobserved characteristics in the reported data. The insights gained from the duration analysis help to identify specific characteristics and areas that operators can address to decrease interruption durations. The findings address specific areas including response plans, incident locations, and maintenance programs where practices and policies could be implemented to reduce shutdown duration. Quantitative interpretation from marginal effects is presented, which can identify the improvement in duration rate for implemented changes. The model was applied to an historical incident in Marshall, Michigan, which confirmed the findings from the model.
    publisherASCE
    titleDuration Analysis of Emergency Shutdown Incidents Regarding Hazardous Liquid Pipelines
    typeJournal Paper
    journal volume34
    journal issue3
    journal titleJournal of Performance of Constructed Facilities
    identifier doi10.1061/(ASCE)CF.1943-5509.0001364
    page04020040
    treeJournal of Performance of Constructed Facilities:;2020:;Volume ( 034 ):;issue: 003
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian