    Sensitivity Analysis of a Heat Exchanger Tube Fitted With Cross-Cut Twisted Tape With Alternate Axis

    Source: Journal of Heat Transfer:;2019:;volume( 141 ):;issue: 004::page 41902
    Author:
    Nakhchi, M. E.
    ,
    Esfahani, J. A.
    DOI: 10.1115/1.4042780
    Publisher: American Society of Mechanical Engineers (ASME)
    Abstract: Numerical simulations are used to analyze the thermal performance of turbulent flow inside heat exchanger tube fitted with cross-cut twisted tape with alternate axis (CCTA). The design parameters include the Reynolds number (5000<Re<15,000), cross-cut width ratio (0.7<b/D<0.9), cross-cut length ratio (2<s/D<2.5), and twist ratio (2<y/D<4). The objective functions are the Nusselt number ratio (Nu/Nus), the friction factor ratio (f/fs), and the thermal performance (η). Response surface method (RSM) is used to construct second-order polynomial correlations as functions of design parameters. The regression analysis shows that heat transfer ratio decreased with increasing both the Reynolds number and the width to diameter ratio of the twisted tape. This means that the twisted tape has more influence on heat transfer at smaller inlet fluid velocities. Sensitivity analysis reveals that among the effective input parameters, the sensitivity of Nu/Nus to the Reynolds number is the highest. The results reveal that thermal performance enhances with increasing the width to diameter ratio of the twisted tape (b/D). The maximum thermal performance factor of 1.531 is obtained for the case of Re=5000, b/D=0.9, s/D=2.5, and y/D=4.
    • Download: (3.545Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      Sensitivity Analysis of a Heat Exchanger Tube Fitted With Cross-Cut Twisted Tape With Alternate Axis

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4258456
    Collections
    • Journal of Heat Transfer

    Show full item record

    contributor authorNakhchi, M. E.
    contributor authorEsfahani, J. A.
    date accessioned2019-09-18T09:04:00Z
    date available2019-09-18T09:04:00Z
    date copyright2/27/2019 12:00:00 AM
    date issued2019
    identifier issn0022-1481
    identifier otherht_141_04_041902.pdf
    identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4258456
    description abstractNumerical simulations are used to analyze the thermal performance of turbulent flow inside heat exchanger tube fitted with cross-cut twisted tape with alternate axis (CCTA). The design parameters include the Reynolds number (5000<Re<15,000), cross-cut width ratio (0.7<b/D<0.9), cross-cut length ratio (2<s/D<2.5), and twist ratio (2<y/D<4). The objective functions are the Nusselt number ratio (Nu/Nus), the friction factor ratio (f/fs), and the thermal performance (η). Response surface method (RSM) is used to construct second-order polynomial correlations as functions of design parameters. The regression analysis shows that heat transfer ratio decreased with increasing both the Reynolds number and the width to diameter ratio of the twisted tape. This means that the twisted tape has more influence on heat transfer at smaller inlet fluid velocities. Sensitivity analysis reveals that among the effective input parameters, the sensitivity of Nu/Nus to the Reynolds number is the highest. The results reveal that thermal performance enhances with increasing the width to diameter ratio of the twisted tape (b/D). The maximum thermal performance factor of 1.531 is obtained for the case of Re=5000, b/D=0.9, s/D=2.5, and y/D=4.
    publisherAmerican Society of Mechanical Engineers (ASME)
    titleSensitivity Analysis of a Heat Exchanger Tube Fitted With Cross-Cut Twisted Tape With Alternate Axis
    typeJournal Paper
    journal volume141
    journal issue4
    journal titleJournal of Heat Transfer
    identifier doi10.1115/1.4042780
    journal fristpage41902
    journal lastpage041902-8
    treeJournal of Heat Transfer:;2019:;volume( 141 ):;issue: 004
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian