    Measurements of Temperature and Emissivity Distributions on a High-Temperature Surface Using an Auxiliary Light Source Method

    Source: Journal of Heat Transfer:;2019:;volume( 141 ):;issue: 008::page 82702
    Author:
    Fu, Tairan
    ,
    Xiong, Yehan
    ,
    Liu, Jiangfan
    ,
    Shi, Congling
    DOI: 10.1115/1.4044010
    Publisher: American Society of Mechanical Engineers (ASME)
    Abstract: A method to simultaneously measure two-dimensional temperature and emissivity distributions on high-temperature diffuse surfaces is developed using an auxiliary light source. The high-temperature diffuse surface is irradiated from the hemispherical space with the auxiliary light source switched “on” or “off.” Two images of the effective radiation intensity are obtained in quick succession for the two states to determine the temperature and emissivity distributions. The measurement method and uncertainty models show that the effect of the unknown emissivity on the accuracy of the temperature field measurement can be eliminated. The optical pyrometer is a color charge coupled device (CCD) sensor with a quartz lamp array used as the auxiliary light source to illustrate the measurement method. An oxidized W–Ni–Fe alloy sample is heated at high temperatures of 600–1000 °C by a 700 W induction-heating device. The distributions of the effective radiation intensities from the sample surface during the “on” and “off” states of the lamp array are measured in the three color channels (R, G, and B channels) to calculate the temperature and emissivity distributions. The temperature measurement uncertainties are less than 4 °C for a temperature range of 600–900 °C. The temperature measurements are experimentally validated by the thermocouple method only with a small temperature difference. The emissivities calculated from the three color channels are very close with a range of 0.855–0.957. The relative uncertainties in the emissivities for channels R and G are less than 2.0%, while the relative uncertainty for channel B data was higher at 2.8% and 7.5% due to lower measurement signals in channel B. This analysis may provide a useful method for measuring the temperatures of high-temperature diffuse surfaces by successfully compensating for the effects of unknown or changing emissivities.
    • Download: (3.534Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      Measurements of Temperature and Emissivity Distributions on a High-Temperature Surface Using an Auxiliary Light Source Method

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4258256
    Collections
    • Journal of Heat Transfer

    Show full item record

    contributor authorFu, Tairan
    contributor authorXiong, Yehan
    contributor authorLiu, Jiangfan
    contributor authorShi, Congling
    date accessioned2019-09-18T09:02:56Z
    date available2019-09-18T09:02:56Z
    date copyright7/3/2019 12:00:00 AM
    date issued2019
    identifier issn0022-1481
    identifier otherht_141_08_082702
    identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4258256
    description abstractA method to simultaneously measure two-dimensional temperature and emissivity distributions on high-temperature diffuse surfaces is developed using an auxiliary light source. The high-temperature diffuse surface is irradiated from the hemispherical space with the auxiliary light source switched “on” or “off.” Two images of the effective radiation intensity are obtained in quick succession for the two states to determine the temperature and emissivity distributions. The measurement method and uncertainty models show that the effect of the unknown emissivity on the accuracy of the temperature field measurement can be eliminated. The optical pyrometer is a color charge coupled device (CCD) sensor with a quartz lamp array used as the auxiliary light source to illustrate the measurement method. An oxidized W–Ni–Fe alloy sample is heated at high temperatures of 600–1000 °C by a 700 W induction-heating device. The distributions of the effective radiation intensities from the sample surface during the “on” and “off” states of the lamp array are measured in the three color channels (R, G, and B channels) to calculate the temperature and emissivity distributions. The temperature measurement uncertainties are less than 4 °C for a temperature range of 600–900 °C. The temperature measurements are experimentally validated by the thermocouple method only with a small temperature difference. The emissivities calculated from the three color channels are very close with a range of 0.855–0.957. The relative uncertainties in the emissivities for channels R and G are less than 2.0%, while the relative uncertainty for channel B data was higher at 2.8% and 7.5% due to lower measurement signals in channel B. This analysis may provide a useful method for measuring the temperatures of high-temperature diffuse surfaces by successfully compensating for the effects of unknown or changing emissivities.
    publisherAmerican Society of Mechanical Engineers (ASME)
    titleMeasurements of Temperature and Emissivity Distributions on a High-Temperature Surface Using an Auxiliary Light Source Method
    typeJournal Paper
    journal volume141
    journal issue8
    journal titleJournal of Heat Transfer
    identifier doi10.1115/1.4044010
    journal fristpage82702
    journal lastpage082702-8
    treeJournal of Heat Transfer:;2019:;volume( 141 ):;issue: 008
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian