YaBeSH Engineering and Technology Library

    • Journals
    • PaperQuest
    • YSE Standards
    • YaBeSH
    • Login
    View Item 
    •   YE&T Library
    • ASME
    • Journal of Heat Transfer
    • View Item
    •   YE&T Library
    • ASME
    • Journal of Heat Transfer
    • View Item
    • All Fields
    • Source Title
    • Year
    • Publisher
    • Title
    • Subject
    • Author
    • DOI
    • ISBN
    Advanced Search
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Archive

    Influence of Geometrical Parameters on Heat Transfer of Transversely Corrugated Helically Coiled Tube for Deicing Fluid

    Source: Journal of Heat Transfer:;2019:;volume( 141 ):;issue: 008::page 81901
    Author:
    Wu, Mengli
    ,
    Nie, Qi
    ,
    Li, Yunpeng
    ,
    Yue, Xianqu
    ,
    Chen, Weibin
    ,
    Wang, Chiyu
    DOI: 10.1115/1.4043835
    Publisher: American Society of Mechanical Engineers (ASME)
    Abstract: In order to ensure flight safety in cold winter, aircraft ground deicing is crucial and necessary. In Chinese deicing fluid heating system, the helically coiled tube is paramount exchanger to heat deicing fluid. The deicing fluid is ethylene-glycol-based mixture with high viscosity. Aiming at heat transfer enhancement of deicing fluid, ring rib is formed by an embossed tube wall toward the internal of the tube; thus, transversely corrugated helically coiled tube (TCHC) is achieved. Depth and width are two key geometrical parameters of ring rib. Based on field synergy principle, the influence of depth–diameter ratio (H/D) and width-diameter ratio (w/D) is investigated through numerical simulation. The results show that outlet temperature, mean convection heat transfer coefficient, and Nusselt number have similar trends, which first increase and then decrease nonlinearly. The variation of flow resistance coefficient is inversely proportional to Reynolds number. Especially, the effect of H/D is more significant than that of w/D. Field synergy angle and velocity field are also analyzed to reveal the mechanism of heat transfer. TCHC performs better than the original tube. Orthogonal experiment calculates the outlet temperature of TCHC when H/D and w/D change. The combination of H/D=0.075 and w/D=0.5 is best solution. TCHC effectively enhances heat transfer of deicing fluid. Therefore, TCHC is beneficial to improve the deicing efficiency and ensure the flight punctuality.
    • Download: (2.809Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      Influence of Geometrical Parameters on Heat Transfer of Transversely Corrugated Helically Coiled Tube for Deicing Fluid

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4258126
    Collections
    • Journal of Heat Transfer

    Show full item record

    contributor authorWu, Mengli
    contributor authorNie, Qi
    contributor authorLi, Yunpeng
    contributor authorYue, Xianqu
    contributor authorChen, Weibin
    contributor authorWang, Chiyu
    date accessioned2019-09-18T09:02:17Z
    date available2019-09-18T09:02:17Z
    date copyright6/12/2019 12:00:00 AM
    date issued2019
    identifier issn0022-1481
    identifier otherht_141_08_081901
    identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4258126
    description abstractIn order to ensure flight safety in cold winter, aircraft ground deicing is crucial and necessary. In Chinese deicing fluid heating system, the helically coiled tube is paramount exchanger to heat deicing fluid. The deicing fluid is ethylene-glycol-based mixture with high viscosity. Aiming at heat transfer enhancement of deicing fluid, ring rib is formed by an embossed tube wall toward the internal of the tube; thus, transversely corrugated helically coiled tube (TCHC) is achieved. Depth and width are two key geometrical parameters of ring rib. Based on field synergy principle, the influence of depth–diameter ratio (H/D) and width-diameter ratio (w/D) is investigated through numerical simulation. The results show that outlet temperature, mean convection heat transfer coefficient, and Nusselt number have similar trends, which first increase and then decrease nonlinearly. The variation of flow resistance coefficient is inversely proportional to Reynolds number. Especially, the effect of H/D is more significant than that of w/D. Field synergy angle and velocity field are also analyzed to reveal the mechanism of heat transfer. TCHC performs better than the original tube. Orthogonal experiment calculates the outlet temperature of TCHC when H/D and w/D change. The combination of H/D=0.075 and w/D=0.5 is best solution. TCHC effectively enhances heat transfer of deicing fluid. Therefore, TCHC is beneficial to improve the deicing efficiency and ensure the flight punctuality.
    publisherAmerican Society of Mechanical Engineers (ASME)
    titleInfluence of Geometrical Parameters on Heat Transfer of Transversely Corrugated Helically Coiled Tube for Deicing Fluid
    typeJournal Paper
    journal volume141
    journal issue8
    journal titleJournal of Heat Transfer
    identifier doi10.1115/1.4043835
    journal fristpage81901
    journal lastpage081901-11
    treeJournal of Heat Transfer:;2019:;volume( 141 ):;issue: 008
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian