YaBeSH Engineering and Technology Library

    • Journals
    • PaperQuest
    • YSE Standards
    • YaBeSH
    • Login
    View Item 
    •   YE&T Library
    • ASME
    • Journal of Medical Devices
    • View Item
    •   YE&T Library
    • ASME
    • Journal of Medical Devices
    • View Item
    • All Fields
    • Source Title
    • Year
    • Publisher
    • Title
    • Subject
    • Author
    • DOI
    • ISBN
    Advanced Search
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Archive

    The Evaluation of a Novel Three-Dimensional Printed Expandable Pedicle Screw Sleeve Insert

    Source: Journal of Medical Devices:;2019:;volume( 013 ):;issue: 003::page 31004
    Author:
    Burkhart, Timothy A.
    ,
    Sadashivaiah, Manjunath
    ,
    Reeves, Jacob
    ,
    Rasounlinejad, Paraham
    DOI: 10.1115/1.4043762
    Publisher: American Society of Mechanical Engineers (ASME)
    Abstract: When used in combination with decompression, spinal fusion is a successful procedure for treating patients with spinal stenosis and degenerative spondylolisthesis. While a number of auxiliary devices have been proposed to enhance the fixation of the screw within the pedicle and vertebral body, there is conflicting information regarding the efficacy of their use. Therefore, the aim of this study was to determine the ability of a novel expandable pedicle screw to improve the fixation of the pedicle screw within the pedicle and vertebral body. A three-dimensional (3D) printed, screw sleeve was designed that expanded within the pedicle and vertebral body when a standard pedicle screw was inserted into it. The left and right pedicle of ten (N = 10) cadaveric lumbar spine specimens (L3–L5) were randomly assigned to be instrumented with either a pedicle screw and the sleeve or a pedicle screw only. Following instrumentation, the screws were exposed to tensile load at 5 mm/min until failure. The failure force, failure deformation, and area under the force–deformation curve were determined and compared between screw conditions. There were no significant differences between the screws and sleeve, and the screw only conditions for the failure force (p = 0.24), failure displacement (p = 0.10), and area under the curve (p = 0.38). While the novel screw sleeve presented here performed as well as a screw without a sleeve, it was better than other screw augmentation devices reported previously. In addition, it is likely that this device would prove useful as an enhancement to revision.
    • Download: (540.6Kb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      The Evaluation of a Novel Three-Dimensional Printed Expandable Pedicle Screw Sleeve Insert

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4258062
    Collections
    • Journal of Medical Devices

    Show full item record

    contributor authorBurkhart, Timothy A.
    contributor authorSadashivaiah, Manjunath
    contributor authorReeves, Jacob
    contributor authorRasounlinejad, Paraham
    date accessioned2019-09-18T09:01:55Z
    date available2019-09-18T09:01:55Z
    date copyright7/15/2019 12:00:00 AM
    date issued2019
    identifier issn1932-6181
    identifier othermed_013_03_031004
    identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4258062
    description abstractWhen used in combination with decompression, spinal fusion is a successful procedure for treating patients with spinal stenosis and degenerative spondylolisthesis. While a number of auxiliary devices have been proposed to enhance the fixation of the screw within the pedicle and vertebral body, there is conflicting information regarding the efficacy of their use. Therefore, the aim of this study was to determine the ability of a novel expandable pedicle screw to improve the fixation of the pedicle screw within the pedicle and vertebral body. A three-dimensional (3D) printed, screw sleeve was designed that expanded within the pedicle and vertebral body when a standard pedicle screw was inserted into it. The left and right pedicle of ten (N = 10) cadaveric lumbar spine specimens (L3–L5) were randomly assigned to be instrumented with either a pedicle screw and the sleeve or a pedicle screw only. Following instrumentation, the screws were exposed to tensile load at 5 mm/min until failure. The failure force, failure deformation, and area under the force–deformation curve were determined and compared between screw conditions. There were no significant differences between the screws and sleeve, and the screw only conditions for the failure force (p = 0.24), failure displacement (p = 0.10), and area under the curve (p = 0.38). While the novel screw sleeve presented here performed as well as a screw without a sleeve, it was better than other screw augmentation devices reported previously. In addition, it is likely that this device would prove useful as an enhancement to revision.
    publisherAmerican Society of Mechanical Engineers (ASME)
    titleThe Evaluation of a Novel Three-Dimensional Printed Expandable Pedicle Screw Sleeve Insert
    typeJournal Paper
    journal volume13
    journal issue3
    journal titleJournal of Medical Devices
    identifier doi10.1115/1.4043762
    journal fristpage31004
    journal lastpage031004-5
    treeJournal of Medical Devices:;2019:;volume( 013 ):;issue: 003
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian