Show simple item record

contributor authorRitchie, David
contributor authorClick, Austin
contributor authorLigrani, Phillip M.
contributor authorLiberatore, Federico
contributor authorPatel, Rajeshriben
contributor authorHo, Yin-Hsiang
date accessioned2019-09-18T09:01:34Z
date available2019-09-18T09:01:34Z
date copyright6/5/2019 12:00:00 AM
date issued2019
identifier issn0742-4795
identifier othergtp_141_09_091008
identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4258002
description abstractConsidered is double wall cooling, with full-coverage effusion-cooling on the hot side of the effusion plate, and a combination of impingement cooling and cross flow cooling, employed together on the cold side of the effusion plate. Data are given for a main stream flow passage with a contraction ratio (CR) of 4 for main stream Reynolds numbers Rems and Rems,avg of 157,000–161,000 and 233,000–244,000, respectively. Hot-side measurements (on the main stream flow or hot side of the effusion plate) are presented, which are measured using infrared thermography. Using a transient thermal measurement approach, measured are spatially resolved distributions of surface adiabatic film cooling effectiveness, and surface heat transfer coefficient. For the same Reynolds number, initial blowing ratio (BR), and streamwise location, increased thermal protection is often provided when the effusion coolant is provided by the cross flow/impingement combination configuration, compared to the cross flow only supply arrangement. In general, higher adiabatic effectiveness values are provided by the impingement only arrangement, relative to the impingement/cross flow combination configuration, when compared at the same Reynolds number, initial BR, and x/de location. Data for one streamwise location of x/de = 60 show that the highest net heat flux reduction line-averaged net heat flux reduction (NHFR) values are produced either by the impingement/cross flow combination configuration or by the impingement only arrangement, depending upon the particular magnitude of BR, which is considered.
publisherAmerican Society of Mechanical Engineers (ASME)
titleDouble Wall Cooling of an Effusion Plate With Simultaneous Cross Flow and Impingement Jet Array Internal Cooling
typeJournal Paper
journal volume141
journal issue9
journal titleJournal of Engineering for Gas Turbines and Power
identifier doi10.1115/1.4043694
journal fristpage91008
journal lastpage091008-11
treeJournal of Engineering for Gas Turbines and Power:;2019:;volume( 141 ):;issue: 009
contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record