YaBeSH Engineering and Technology Library

    • Journals
    • PaperQuest
    • YSE Standards
    • YaBeSH
    • Login
    View Item 
    •   YE&T Library
    • ASME
    • Journal of Medical Devices
    • View Item
    •   YE&T Library
    • ASME
    • Journal of Medical Devices
    • View Item
    • All Fields
    • Source Title
    • Year
    • Publisher
    • Title
    • Subject
    • Author
    • DOI
    • ISBN
    Advanced Search
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Archive

    A Hand-Held Device to Apply Instrument-Assisted Soft Tissue Mobilization at Targeted Compression Forces and Stroke Frequencies

    Source: Journal of Medical Devices:;2019:;volume( 013 ):;issue: 001::page 14504
    Author:
    Everingham, John B.
    ,
    Martin, Peter T.
    ,
    Lujan, Trevor J.
    DOI: 10.1115/1.4041696
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: Instrument-assisted soft tissue mobilization (IASTM) is a manual therapy technique that is commonly used to treat dysfunctions in ligaments and other musculoskeletal tissues. The objective of this study was to develop a simple hand-held device that helps users accurately apply targeted compressive forces and stroke frequencies during IASTM treatments. This portable device uses a force sensor, tablet computer, and custom software to guide the application of user-specified loading parameters. To measure performance, the device was used to apply a combination of targeted forces and stroke frequencies to foam blocks and silicone pads. Three operators using the device applied targeted forces between 0.3 and 125 N with less than 10% error and applied targeted stroke frequencies between 0.25 and 1.0 Hz with less than 3% error. The mean error in applying targeted forces increased significantly at compressive forces less than 0.2 N and greater than 125 N. For experimental validation, the device was used to apply a series of IASTM treatments over three-weeks to rodents with a ligament injury, and the targeted compressive force and stroke frequency were repeatedly applied with an average error less than 5%. This validated device can be used to investigate the effect of IASTM loading parameters on tissue healing in animal and human studies, and therefore can support the optimization and adoption of IASTM protocols that improve patient outcomes.
    • Download: (932.7Kb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      A Hand-Held Device to Apply Instrument-Assisted Soft Tissue Mobilization at Targeted Compression Forces and Stroke Frequencies

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4256526
    Collections
    • Journal of Medical Devices

    Show full item record

    contributor authorEveringham, John B.
    contributor authorMartin, Peter T.
    contributor authorLujan, Trevor J.
    date accessioned2019-03-17T11:00:53Z
    date available2019-03-17T11:00:53Z
    date copyright12/4/2018 12:00:00 AM
    date issued2019
    identifier issn1932-6181
    identifier othermed_013_01_014504.pdf
    identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4256526
    description abstractInstrument-assisted soft tissue mobilization (IASTM) is a manual therapy technique that is commonly used to treat dysfunctions in ligaments and other musculoskeletal tissues. The objective of this study was to develop a simple hand-held device that helps users accurately apply targeted compressive forces and stroke frequencies during IASTM treatments. This portable device uses a force sensor, tablet computer, and custom software to guide the application of user-specified loading parameters. To measure performance, the device was used to apply a combination of targeted forces and stroke frequencies to foam blocks and silicone pads. Three operators using the device applied targeted forces between 0.3 and 125 N with less than 10% error and applied targeted stroke frequencies between 0.25 and 1.0 Hz with less than 3% error. The mean error in applying targeted forces increased significantly at compressive forces less than 0.2 N and greater than 125 N. For experimental validation, the device was used to apply a series of IASTM treatments over three-weeks to rodents with a ligament injury, and the targeted compressive force and stroke frequency were repeatedly applied with an average error less than 5%. This validated device can be used to investigate the effect of IASTM loading parameters on tissue healing in animal and human studies, and therefore can support the optimization and adoption of IASTM protocols that improve patient outcomes.
    publisherThe American Society of Mechanical Engineers (ASME)
    titleA Hand-Held Device to Apply Instrument-Assisted Soft Tissue Mobilization at Targeted Compression Forces and Stroke Frequencies
    typeJournal Paper
    journal volume13
    journal issue1
    journal titleJournal of Medical Devices
    identifier doi10.1115/1.4041696
    journal fristpage14504
    journal lastpage014504-5
    treeJournal of Medical Devices:;2019:;volume( 013 ):;issue: 001
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian