Show simple item record

contributor authorShrager, Adam C.
contributor authorThole, Karen A.
contributor authorMongillo, Dominic
date accessioned2019-03-17T10:25:00Z
date available2019-03-17T10:25:00Z
date copyright10/15/2018 12:00:00 AM
date issued2019
identifier issn0742-4795
identifier othergtp_141_01_011022.pdf
identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4256127
description abstractThe complex flow field in a gas turbine combustor makes cooling the liner walls a challenge. In particular, this paper is primarily focused on the region surrounding the dilution holes, which is especially challenging to cool due to the interaction between the effusion cooling jets and high-momentum dilution jets. This study presents overall effectiveness measurements for three different cooling hole patterns of a double-walled combustor liner. Only effusion hole patterns near the dilution holes were varied, which included: no effusion cooling; effusion holes pointed radially outward from the dilution hole; and effusion holes pointed radially inward toward the dilution hole. The double-walled liner contained both impingement and effusion plates as well as a row of dilution jets. Infrared thermography was used to measure the surface temperature of the combustor liners at multiple dilution jet momentum flux ratios and approaching freestream turbulence intensities of 0.5% and 13%. Results showed that the outward and inward geometries were able to more effectively cool the region surrounding the dilution hole compared to the closed case. A significant amount of the cooling enhancement in the outward and inward cases came from in-hole convection. Downstream of the dilution hole, the interactions between the inward effusion holes and the dilution jet led to lower levels of effectiveness compared to the other two geometries. High freestream turbulence caused a small decrease in overall effectiveness over the entire liner and was most impactful in the first three rows of effusion holes.
publisherThe American Society of Mechanical Engineers (ASME)
titleEffects of Effusion Cooling Pattern Near the Dilution Hole for a Double-Walled Combustor Liner—Part 1: Overall Effectiveness Measurements
typeJournal Paper
journal volume141
journal issue1
journal titleJournal of Engineering for Gas Turbines and Power
identifier doi10.1115/1.4041148
journal fristpage11022
journal lastpage011022-10
treeJournal of Engineering for Gas Turbines and Power:;2019:;volume( 141 ):;issue: 001
contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record