    Modeling Skeletal Muscle Stress and Intramuscular Pressure: A Whole Muscle Active–Passive Approach

    Source: Journal of Biomechanical Engineering:;2018:;volume( 140 ):;issue: 008::page 81006
    Author:
    Wheatley, Benjamin B.
    ,
    Odegard, Gregory M.
    ,
    Kaufman, Kenton R.
    ,
    Haut Donahue, Tammy L.
    DOI: 10.1115/1.4040318
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: Clinical treatments of skeletal muscle weakness are hindered by a lack of an approach to evaluate individual muscle force. Intramuscular pressure (IMP) has shown a correlation to muscle force in vivo, but patient to patient and muscle to muscle variability results in difficulty of utilizing IMP to estimate muscle force. The goal of this work was to develop a finite element model of whole skeletal muscle that can predict IMP under passive and active conditions to further investigate the mechanisms of IMP variability. A previously validated hypervisco-poroelastic constitutive approach was modified to incorporate muscle activation through an inhomogeneous geometry. Model parameters were optimized to fit model stress to experimental data, and the resulting model fluid pressurization data were utilized for validation. Model fitting was excellent (root-mean-square error or RMSE <1.5 kPa for passive and active conditions), and IMP predictive capability was strong for both passive (RMSE 3.5 mmHg) and active (RMSE 10 mmHg at in vivo lengths) conditions. Additionally, model fluid pressure was affected by length under isometric conditions, as increases in stretch yielded decreases in fluid pressurization following a contraction, resulting from counteracting Poisson effects. Model pressure also varied spatially, with the highest gradients located near aponeuroses. These findings may explain variability of in vivo IMP measurements in the clinic, and thus help reduce this variability in future studies. Further development of this model to include isotonic contractions and muscle weakness would greatly benefit this work.
    • Download: (1.230Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      Modeling Skeletal Muscle Stress and Intramuscular Pressure: A Whole Muscle Active–Passive Approach

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4253643
    Collections
    • Journal of Biomechanical Engineering

    Show full item record

    contributor authorWheatley, Benjamin B.
    contributor authorOdegard, Gregory M.
    contributor authorKaufman, Kenton R.
    contributor authorHaut Donahue, Tammy L.
    date accessioned2019-02-28T11:11:28Z
    date available2019-02-28T11:11:28Z
    date copyright6/1/2018 12:00:00 AM
    date issued2018
    identifier issn0148-0731
    identifier otherbio_140_08_081006.pdf
    identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4253643
    description abstractClinical treatments of skeletal muscle weakness are hindered by a lack of an approach to evaluate individual muscle force. Intramuscular pressure (IMP) has shown a correlation to muscle force in vivo, but patient to patient and muscle to muscle variability results in difficulty of utilizing IMP to estimate muscle force. The goal of this work was to develop a finite element model of whole skeletal muscle that can predict IMP under passive and active conditions to further investigate the mechanisms of IMP variability. A previously validated hypervisco-poroelastic constitutive approach was modified to incorporate muscle activation through an inhomogeneous geometry. Model parameters were optimized to fit model stress to experimental data, and the resulting model fluid pressurization data were utilized for validation. Model fitting was excellent (root-mean-square error or RMSE <1.5 kPa for passive and active conditions), and IMP predictive capability was strong for both passive (RMSE 3.5 mmHg) and active (RMSE 10 mmHg at in vivo lengths) conditions. Additionally, model fluid pressure was affected by length under isometric conditions, as increases in stretch yielded decreases in fluid pressurization following a contraction, resulting from counteracting Poisson effects. Model pressure also varied spatially, with the highest gradients located near aponeuroses. These findings may explain variability of in vivo IMP measurements in the clinic, and thus help reduce this variability in future studies. Further development of this model to include isotonic contractions and muscle weakness would greatly benefit this work.
    publisherThe American Society of Mechanical Engineers (ASME)
    titleModeling Skeletal Muscle Stress and Intramuscular Pressure: A Whole Muscle Active–Passive Approach
    typeJournal Paper
    journal volume140
    journal issue8
    journal titleJournal of Biomechanical Engineering
    identifier doi10.1115/1.4040318
    journal fristpage81006
    journal lastpage081006-8
    treeJournal of Biomechanical Engineering:;2018:;volume( 140 ):;issue: 008
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian