    Validation of the Strain Assessment of a Phantom of Abdominal Aortic Aneurysm: Comparison of Results Obtained From Magnetic Resonance Imaging and Stereovision Measurements

    Source: Journal of Biomechanical Engineering:;2018:;volume( 140 ):;issue: 003::page 31001
    Author:
    Wang, Yufei
    ,
    Joannic, David
    ,
    Juillion, Patrick
    ,
    Monnet, Aurélien
    ,
    Delassus, Patrick
    ,
    Lalande, Alain
    ,
    Fontaine, Jean-François
    DOI: 10.1115/1.4038743
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: Predicting aortic aneurysm ruptures is a complex problem that has been investigated by many research teams over several decades. Work on this issue is notably complex and involves both the mechanical behavior of the artery and the blood flow. Magnetic resonance imaging (MRI) can provide measurements concerning the shape of an organ and the blood that flows through it. Measuring local distortion of the artery wall is the first essential factor to evaluate in a ruptured artery. This paper aims to demonstrate the feasibility of this measure using MRI on a phantom of an abdominal aortic aneurysm (AAA) with realistic shape. The aortic geometry is obtained from a series of cine-MR images and reconstructed using Mimics software. From 4D flow and MRI measurements, the field of velocity is determined and introduced into a computational fluid dynamic (CFD) model to determine the mechanical boundaries applied on the wall artery (pressure and ultimately wall shear stress (WSS)). These factors are then converted into a solid model that enables wall deformations to be calculated. This approach was applied to a silicone phantom model of an AAA reconstructed from a patient's computed tomography-scan examination. The calculated deformations were then compared to those obtained in identical conditions by stereovision. The results of both methods were found to be close. Deformations of the studied AAA phantom with complex shape were obtained within a gap of 12% by modeling from MR data.
    • Download: (5.525Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      Validation of the Strain Assessment of a Phantom of Abdominal Aortic Aneurysm: Comparison of Results Obtained From Magnetic Resonance Imaging and Stereovision Measurements

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4253640
    Collections
    • Journal of Biomechanical Engineering

    Show full item record

    contributor authorWang, Yufei
    contributor authorJoannic, David
    contributor authorJuillion, Patrick
    contributor authorMonnet, Aurélien
    contributor authorDelassus, Patrick
    contributor authorLalande, Alain
    contributor authorFontaine, Jean-François
    date accessioned2019-02-28T11:11:27Z
    date available2019-02-28T11:11:27Z
    date copyright1/17/2018 12:00:00 AM
    date issued2018
    identifier issn0148-0731
    identifier otherbio_140_03_031001.pdf
    identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4253640
    description abstractPredicting aortic aneurysm ruptures is a complex problem that has been investigated by many research teams over several decades. Work on this issue is notably complex and involves both the mechanical behavior of the artery and the blood flow. Magnetic resonance imaging (MRI) can provide measurements concerning the shape of an organ and the blood that flows through it. Measuring local distortion of the artery wall is the first essential factor to evaluate in a ruptured artery. This paper aims to demonstrate the feasibility of this measure using MRI on a phantom of an abdominal aortic aneurysm (AAA) with realistic shape. The aortic geometry is obtained from a series of cine-MR images and reconstructed using Mimics software. From 4D flow and MRI measurements, the field of velocity is determined and introduced into a computational fluid dynamic (CFD) model to determine the mechanical boundaries applied on the wall artery (pressure and ultimately wall shear stress (WSS)). These factors are then converted into a solid model that enables wall deformations to be calculated. This approach was applied to a silicone phantom model of an AAA reconstructed from a patient's computed tomography-scan examination. The calculated deformations were then compared to those obtained in identical conditions by stereovision. The results of both methods were found to be close. Deformations of the studied AAA phantom with complex shape were obtained within a gap of 12% by modeling from MR data.
    publisherThe American Society of Mechanical Engineers (ASME)
    titleValidation of the Strain Assessment of a Phantom of Abdominal Aortic Aneurysm: Comparison of Results Obtained From Magnetic Resonance Imaging and Stereovision Measurements
    typeJournal Paper
    journal volume140
    journal issue3
    journal titleJournal of Biomechanical Engineering
    identifier doi10.1115/1.4038743
    journal fristpage31001
    journal lastpage031001-9
    treeJournal of Biomechanical Engineering:;2018:;volume( 140 ):;issue: 003
    contenttypeFulltext