    Predicting Rotation in Fenestrated Endovascular Aneurysm Repair Using Finite Element Analysis

    Source: Journal of Biomechanical Engineering:;2018:;volume( 140 ):;issue: 009::page 91004
    Author:
    Sanford, Ryan M.
    ,
    Crawford, Sean A.
    ,
    Genis, Helen
    ,
    Doyle, Matthew G.
    ,
    Forbes, Thomas L.
    ,
    Amon, Cristina H.
    DOI: 10.1115/1.4040124
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: Fenestrated endovascular aneurysm repair (FEVAR) is a minimally invasive method of abdominal aortic aneurysm (AAA) repair utilized in patients with complex vessel anatomies. Stent grafts (SG) used in this process contain fenestrations within the device that need to be aligned with the visceral arteries upon successful SG deployment. Proper alignment is crucial to maintain blood flow to these arteries and avoid surgical complications. During fenestrated SG deployment, rotation of the SG can occur during the unsheathing process. This leads to misalignment of the vessels, and the fenestrations and is associated with poor clinical outcomes. The aim of this study was to develop a computational model of the FEVAR process to predict SG rotation. Six patient-specific cases are presented and compared with surgical case data. Realistic material properties, frictional effects, deployment methods, and boundary conditions are included in the model. A mean simulation error of 2 deg (range 1–4 deg) was observed. This model was then used to conduct a parameter study of frictional properties to see if rotation could be minimized. This study showed that increasing or decreasing the coefficients of friction (COF) between the sheath and the vessel walls would decrease the amount of rotation observed. Our model accurately predicts the amount of SG rotation observed during FEVAR and can be used as a preoperative planning tool within the surgical workflow.
    • Download: (1.073Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      Predicting Rotation in Fenestrated Endovascular Aneurysm Repair Using Finite Element Analysis

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4253614
    Collections
    • Journal of Biomechanical Engineering

    Show full item record

    contributor authorSanford, Ryan M.
    contributor authorCrawford, Sean A.
    contributor authorGenis, Helen
    contributor authorDoyle, Matthew G.
    contributor authorForbes, Thomas L.
    contributor authorAmon, Cristina H.
    date accessioned2019-02-28T11:11:19Z
    date available2019-02-28T11:11:19Z
    date copyright5/24/2018 12:00:00 AM
    date issued2018
    identifier issn0148-0731
    identifier otherbio_140_09_091004.pdf
    identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4253614
    description abstractFenestrated endovascular aneurysm repair (FEVAR) is a minimally invasive method of abdominal aortic aneurysm (AAA) repair utilized in patients with complex vessel anatomies. Stent grafts (SG) used in this process contain fenestrations within the device that need to be aligned with the visceral arteries upon successful SG deployment. Proper alignment is crucial to maintain blood flow to these arteries and avoid surgical complications. During fenestrated SG deployment, rotation of the SG can occur during the unsheathing process. This leads to misalignment of the vessels, and the fenestrations and is associated with poor clinical outcomes. The aim of this study was to develop a computational model of the FEVAR process to predict SG rotation. Six patient-specific cases are presented and compared with surgical case data. Realistic material properties, frictional effects, deployment methods, and boundary conditions are included in the model. A mean simulation error of 2 deg (range 1–4 deg) was observed. This model was then used to conduct a parameter study of frictional properties to see if rotation could be minimized. This study showed that increasing or decreasing the coefficients of friction (COF) between the sheath and the vessel walls would decrease the amount of rotation observed. Our model accurately predicts the amount of SG rotation observed during FEVAR and can be used as a preoperative planning tool within the surgical workflow.
    publisherThe American Society of Mechanical Engineers (ASME)
    titlePredicting Rotation in Fenestrated Endovascular Aneurysm Repair Using Finite Element Analysis
    typeJournal Paper
    journal volume140
    journal issue9
    journal titleJournal of Biomechanical Engineering
    identifier doi10.1115/1.4040124
    journal fristpage91004
    journal lastpage091004-8
    treeJournal of Biomechanical Engineering:;2018:;volume( 140 ):;issue: 009
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian