    An Ergonomic Testing System for the First Metatarsophalangeal Joint Stiffness

    Source: Journal of Biomechanical Engineering:;2018:;volume( 140 ):;issue: 010::page 104501
    Author:
    Farhadi, Fatemeh
    ,
    Faraz, Muhammad
    ,
    Heng, Marabelle
    ,
    Johnson, Shane
    DOI: 10.1115/1.4040248
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: Osteoarthritis sufferers commonly have first metatarsophalangeal joint (MTPJ) problems in which articular surfaces are changed permanently due to fatigue. Therefore, medical devices for early diagnosis would increase the opportunity for prevention of disease progression. In previous studies on stiffness of the first MTPJ many details, although functionally of great importance, have not been fully considered including: design and size of the device, tribology consideration, and errors from device. Therefore, the motivation of our research was to enhance the device design by reducing the size of the device, and device design was enhanced by minimizing measurement errors through development of a new ergonomic left and right foot instrument located medial to the first MTPJ (instead of beneath the foot). The first MTPJ stiffness (N mm/kg radian) measurement was taken on 28 subjects with two replicates per subject by the same tester. The first MTPJ stiffness ranged from 3.49 to 14.42 N mm/kg radian with the mean (SD) value of 8.28 (3.15) N mm/kg radian for the left feet and 3.91 to 11.90 N mm/kg radian with the mean (SD) value of 7.65 (2.07) N mm/kg radian for the right feet. Reliability evaluation was measured using intraclass correlation coefficient and described an excellent reliability between two tests.
    • Download: (1.168Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      An Ergonomic Testing System for the First Metatarsophalangeal Joint Stiffness

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4253421
    Collections
    • Journal of Biomechanical Engineering

    Show full item record

    contributor authorFarhadi, Fatemeh
    contributor authorFaraz, Muhammad
    contributor authorHeng, Marabelle
    contributor authorJohnson, Shane
    date accessioned2019-02-28T11:10:14Z
    date available2019-02-28T11:10:14Z
    date copyright6/21/2018 12:00:00 AM
    date issued2018
    identifier issn0148-0731
    identifier otherbio_140_10_104501.pdf
    identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4253421
    description abstractOsteoarthritis sufferers commonly have first metatarsophalangeal joint (MTPJ) problems in which articular surfaces are changed permanently due to fatigue. Therefore, medical devices for early diagnosis would increase the opportunity for prevention of disease progression. In previous studies on stiffness of the first MTPJ many details, although functionally of great importance, have not been fully considered including: design and size of the device, tribology consideration, and errors from device. Therefore, the motivation of our research was to enhance the device design by reducing the size of the device, and device design was enhanced by minimizing measurement errors through development of a new ergonomic left and right foot instrument located medial to the first MTPJ (instead of beneath the foot). The first MTPJ stiffness (N mm/kg radian) measurement was taken on 28 subjects with two replicates per subject by the same tester. The first MTPJ stiffness ranged from 3.49 to 14.42 N mm/kg radian with the mean (SD) value of 8.28 (3.15) N mm/kg radian for the left feet and 3.91 to 11.90 N mm/kg radian with the mean (SD) value of 7.65 (2.07) N mm/kg radian for the right feet. Reliability evaluation was measured using intraclass correlation coefficient and described an excellent reliability between two tests.
    publisherThe American Society of Mechanical Engineers (ASME)
    titleAn Ergonomic Testing System for the First Metatarsophalangeal Joint Stiffness
    typeJournal Paper
    journal volume140
    journal issue10
    journal titleJournal of Biomechanical Engineering
    identifier doi10.1115/1.4040248
    journal fristpage104501
    journal lastpage104501-6
    treeJournal of Biomechanical Engineering:;2018:;volume( 140 ):;issue: 010
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian