The Effect of External Casing Impingement Cooling Manifold Standoff Distance on Casing Contraction for Thermal Control of Blade Tip ClearanceSource: Journal of Turbomachinery:;2018:;volume 140:;issue 002::page 21005DOI: 10.1115/1.4038280Publisher: The American Society of Mechanical Engineers (ASME)
Abstract: Thermal closure of the engine casing is widely used to minimize undesirable blade tip leakage flows thus improving jet engine performance. This may be achieved using an impingement cooling scheme on the external casing wall, provided by manifolds attached to the outside of the engine. The assembly tolerance of these components leads to variation in the standoff distance between the manifold and the casing, and its effects on casing contraction must be understood to allow build tolerance to be specified. For cooling arrangements with promising performance, the variation in closure with standoff distance of z/d = 1–6 were investigated through a mixture of extensive numerical modeling and experimental validation. A cooling manifold, typical of that adopted by several engine companies, incorporating three different arrays of short cooling holes (chosen from previous study by Choi et al. (2016, “The Relative Performance of External Casing Impingement Cooling Arrangements for Thermal Control of Blade Tip Clearance,” ASME J. Turbomach., 138(3), p. 031005.)) and thermal control dummy flanges were considered. Typical contractions of 0.5–2.2 mm are achieved from the 0.02–0.35 kg/s of the current casing cooling flows. The variation in heat transfer coefficient observed with standoff distance is much lower for the sparse array investigated compared to previous designs employing arrays typical of blade cooling configurations. The reason for this is explained through interrogation of the local flow field and resultant heat transfer coefficient. This implies that acceptable control of the circumferential uniformity of case cooling can be achieved with relatively large assembly tolerance of the manifold relative to the casing.
|
Collections
Show full item record
| contributor author | Choi, Myeonggeun | |
| contributor author | Gillespie, David R. H. | |
| contributor author | Lewis, Leo V. | |
| date accessioned | 2019-02-28T11:09:26Z | |
| date available | 2019-02-28T11:09:26Z | |
| date copyright | 11/29/2017 12:00:00 AM | |
| date issued | 2018 | |
| identifier issn | 0889-504X | |
| identifier other | turbo_140_02_021005.pdf | |
| identifier uri | http://yetl.yabesh.ir/yetl1/handle/yetl/4253277 | |
| description abstract | Thermal closure of the engine casing is widely used to minimize undesirable blade tip leakage flows thus improving jet engine performance. This may be achieved using an impingement cooling scheme on the external casing wall, provided by manifolds attached to the outside of the engine. The assembly tolerance of these components leads to variation in the standoff distance between the manifold and the casing, and its effects on casing contraction must be understood to allow build tolerance to be specified. For cooling arrangements with promising performance, the variation in closure with standoff distance of z/d = 1–6 were investigated through a mixture of extensive numerical modeling and experimental validation. A cooling manifold, typical of that adopted by several engine companies, incorporating three different arrays of short cooling holes (chosen from previous study by Choi et al. (2016, “The Relative Performance of External Casing Impingement Cooling Arrangements for Thermal Control of Blade Tip Clearance,” ASME J. Turbomach., 138(3), p. 031005.)) and thermal control dummy flanges were considered. Typical contractions of 0.5–2.2 mm are achieved from the 0.02–0.35 kg/s of the current casing cooling flows. The variation in heat transfer coefficient observed with standoff distance is much lower for the sparse array investigated compared to previous designs employing arrays typical of blade cooling configurations. The reason for this is explained through interrogation of the local flow field and resultant heat transfer coefficient. This implies that acceptable control of the circumferential uniformity of case cooling can be achieved with relatively large assembly tolerance of the manifold relative to the casing. | |
| publisher | The American Society of Mechanical Engineers (ASME) | |
| title | The Effect of External Casing Impingement Cooling Manifold Standoff Distance on Casing Contraction for Thermal Control of Blade Tip Clearance | |
| type | Journal Paper | |
| journal volume | 140 | |
| journal issue | 2 | |
| journal title | Journal of Turbomachinery | |
| identifier doi | 10.1115/1.4038280 | |
| journal fristpage | 21005 | |
| journal lastpage | 021005-13 | |
| tree | Journal of Turbomachinery:;2018:;volume 140:;issue 002 | |
| contenttype | Fulltext |