Show simple item record

contributor authorNouri, Bijan
contributor authorRöger, Marc
contributor authorJanotte, Nicole
contributor authorHilgert, Christoph
date accessioned2019-02-28T11:08:05Z
date available2019-02-28T11:08:05Z
date copyright3/28/2018 12:00:00 AM
date issued2018
identifier issn1948-5085
identifier othertsea_010_03_031011.pdf
identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4253045
description abstractA clamp-on measurement system for flexible and accurate fluid temperature measurements for turbulent flows with Reynolds numbers higher than 30,000 is presented in this paper. This noninvasive system can be deployed without interference with the fluid flow while delivering the high accuracies necessary for performance and acceptance testing for power plants in terms of measurement accuracy and position. The system is experimentally validated in the fluid flow of a solar thermal parabolic trough collector test bench, equipped with built-in sensors as reference. Its applicability under industrial conditions is demonstrated at the 50 MWel AndaSol-3 parabolic trough solar power plant in Spain. A function based on large experimental data correcting the temperature gradient between the measured clamp-on sensor and actual fluid temperature is developed, achieving an uncertainty below ±0.7 K (2σ) for fluid temperatures up to 400 °C. In addition, the experimental results are used to validate a numerical model. Based on the results of this model, a general dimensionless correction function for a wider range of application scenarios is derived. The clamp-on system, together with the dimensionless correction function, supports numerous combinations of fluids, pipe materials, insulations, geometries, and operation conditions and should be useful in a variety of industrial applications of the power and chemical industry where temporal noninvasive fluid temperature measurement is needed with good accuracy. The comparison of the general dimensionless correction function with measurement data indicates a measurement uncertainty below 1 K (2σ).
publisherThe American Society of Mechanical Engineers (ASME)
titleCharacterization and Corrections for Clamp-On Fluid Temperature Measurements in Turbulent Flows
typeJournal Paper
journal volume10
journal issue3
journal titleJournal of Thermal Science and Engineering Applications
identifier doi10.1115/1.4038706
journal fristpage31011
journal lastpage031011-11
treeJournal of Thermal Science and Engineering Applications:;2018:;volume( 010 ):;issue: 003
contenttypeFulltext