Show simple item record

contributor authorSoopee, Asif
contributor authorKhoodaruth, Abdel Anwar Hossen
contributor authorMurdan, Anshu Prakash
contributor authorOree, Vishwamitra
date accessioned2019-02-28T11:07:32Z
date available2019-02-28T11:07:32Z
date copyright7/24/2018 12:00:00 AM
date issued2018
identifier issn0199-6231
identifier othersol_140_06_061014.pdf
identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4252947
description abstractThe effects of thermal separators within the evacuated tubes of a water-in-glass solar water heater (SWH) were numerically investigated using the commercial computational fluid dynamics (CFD) software ANSYS fluent. To validate the three-dimensional (3D) model, an experiment was performed for the passive operation of the SWH for a fortnight period, of which 3 h of recorded data was selected. The Boussinesq's approximation was employed, and the respective solar irradiance and ambient temperature profiles were incorporated. A maximum deviation of only 2.06% was observed between the experimental and numerical results. The model was then adapted for the case where thermal separators are inserted within the evacuated tubes of the SWH and both cases were run for two tilt angles, 10 deg and 40 deg. The temperature and velocity profiles within the evacuated tubes were analyzed alongside the temperature contours, thermal stratification, and overall thermal efficiency of the SWH. At a 40 deg tilt, without thermal separators, the flow streams within the evacuated tubes are restrained, and a chaotic thermal behavior was observed, thereby restricting thermal distribution to the water stored in the SWH tank. A lower tilt angle (10 deg) provided a more desirable thermal distribution. With thermal separators, however, the tilt angle preference was reversed. A faster and more uniform thermal distribution was achieved within the water tank, with a sizeable reduction in the thermal stratification at a 40 deg tilt. The overall thermal efficiency of the SWH was improved by 4.11% and 4.14% for tilt angles of 10 deg and 40 deg, respectively.
publisherThe American Society of Mechanical Engineers (ASME)
titleNumerical Investigation of Thermal Separators Within the Evacuated Tubes of a Water-in-Glass Solar Water Heater
typeJournal Paper
journal volume140
journal issue6
journal titleJournal of Solar Energy Engineering
identifier doi10.1115/1.4040758
journal fristpage61014
journal lastpage061014-13
treeJournal of Solar Energy Engineering:;2018:;volume( 140 ):;issue: 006
contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record