    A Temporary Local Rigid Clamping Structure to Improve Antibuckling Ability of the Thin-Walled Cylinder Under External Pressure

    Source: Journal of Pressure Vessel Technology:;2018:;volume( 140 ):;issue: 004::page 41203
    Author:
    Gao, BingJun
    ,
    Yin, Zongxun
    ,
    Zhao, Fuhai
    ,
    Shang, Chengwen
    DOI: 10.1115/1.4040496
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: Although the inner container of the cryogenic liquid semitrailer works under inner pressure, it needs to be vacuumed during the helium leak detection. Furthermore, the inner container usually cannot meet the stability requirements during the evacuation, though equipped with stiffening structures such as supporting rings for baffles inside the container. Therefore, a kind of temporary local rigid clamping structure was proposed to improve the antibuckling ability of the inner container during the helium leak detection. “Lulu” can was taken as the thin-walled cylindrical shell specimen under external pressure and was clamped with the temporary local rigid ring on the outside surface. The critical pressures were experimentally and numerically studied for the specimen with local clamping rings of different sizes, in which eigenvalue buckling analysis and nonlinear analysis were employed with the aid of ANSYS. It indicates that the critical pressure of the specimen with the local clamping ring is higher than that without the clamping ring. Finally, the optimal clamping scheme including size and location of clamping rings for the inner container of DC18 type cryogenic liquid semitrailer was studied with the finite element method, which aimed to improve the antibuckling capacity of the inner container during the helium leak detection.
    • Download: (5.710Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      A Temporary Local Rigid Clamping Structure to Improve Antibuckling Ability of the Thin-Walled Cylinder Under External Pressure

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4252786
    Collections
    • Journal of Pressure Vessel Technology

    Show full item record

    contributor authorGao, BingJun
    contributor authorYin, Zongxun
    contributor authorZhao, Fuhai
    contributor authorShang, Chengwen
    date accessioned2019-02-28T11:06:39Z
    date available2019-02-28T11:06:39Z
    date copyright6/26/2018 12:00:00 AM
    date issued2018
    identifier issn0094-9930
    identifier otherpvt_140_04_041203.pdf
    identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4252786
    description abstractAlthough the inner container of the cryogenic liquid semitrailer works under inner pressure, it needs to be vacuumed during the helium leak detection. Furthermore, the inner container usually cannot meet the stability requirements during the evacuation, though equipped with stiffening structures such as supporting rings for baffles inside the container. Therefore, a kind of temporary local rigid clamping structure was proposed to improve the antibuckling ability of the inner container during the helium leak detection. “Lulu” can was taken as the thin-walled cylindrical shell specimen under external pressure and was clamped with the temporary local rigid ring on the outside surface. The critical pressures were experimentally and numerically studied for the specimen with local clamping rings of different sizes, in which eigenvalue buckling analysis and nonlinear analysis were employed with the aid of ANSYS. It indicates that the critical pressure of the specimen with the local clamping ring is higher than that without the clamping ring. Finally, the optimal clamping scheme including size and location of clamping rings for the inner container of DC18 type cryogenic liquid semitrailer was studied with the finite element method, which aimed to improve the antibuckling capacity of the inner container during the helium leak detection.
    publisherThe American Society of Mechanical Engineers (ASME)
    titleA Temporary Local Rigid Clamping Structure to Improve Antibuckling Ability of the Thin-Walled Cylinder Under External Pressure
    typeJournal Paper
    journal volume140
    journal issue4
    journal titleJournal of Pressure Vessel Technology
    identifier doi10.1115/1.4040496
    journal fristpage41203
    journal lastpage041203-11
    treeJournal of Pressure Vessel Technology:;2018:;volume( 140 ):;issue: 004
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian