    A Novel Graft Fixation Technique for Anterior Cruciate Ligament Reconstruction Using Hamstring Tendon Grafts

    Source: Journal of Medical Devices:;2018:;volume( 012 ):;issue: 001::page 11004
    Author:
    Li, Guoan
    ,
    Hosseini, Ali
    ,
    Gadikota, Hemanth
    ,
    Gill, Thomas
    DOI: 10.1115/1.4038307
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: This study evaluated the biomechanical efficacy of single-tunnel double-bundle anterior cruciate ligament (ACL) reconstruction technique. The graft construct is achieved using a novel fixation device that splits an ACL (SPACL) graft into two bundles, recreating the anteromedial (AM) and posterolateral (PL) bundles for ACL reconstruction. A pullout strength test of the SPACL was performed using a 7-mm bovine digital extensor tendon graft. The capability in restoration of knee kinematics after SPACL reconstruction was investigated using cadaveric human knees on a robotic testing system under an anterior tibial load of 134 N and a simulated quadriceps load of 400 N. The data indicated that the SPACL graft has a pullout strength of 823.7±172.3 N. Under the 134 N anterior tibial load, the anteroposterior joint laxity had increased constraint using the SPACL reconstruction but not significantly (p > 0.05) at all selected flexion angles. Under the 400 N quadriceps load, no significant differences were observed between the anterior tibial translation of intact knee and SPACL conditions at all selected flexion angles, but the SPACL graft induced a significant increase in external tibial rotation compared to the intact knee condition at all selected flexion angles with a maximal external rotation of −3.20 deg ±3.6 deg at 90 deg flexion. These data showed that the SPACL technique is equivalent or superior to existing ACL reconstruction techniques in restoration of knee laxity and kinematics. The new SPACL reconstruction technique could provide a valuable alternation to contemporary ACL reconstruction surgery by more closely recreating native ACL kinematics.
    • Download: (656.2Kb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      A Novel Graft Fixation Technique for Anterior Cruciate Ligament Reconstruction Using Hamstring Tendon Grafts

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4252460
    Collections
    • Journal of Medical Devices

    Show full item record

    contributor authorLi, Guoan
    contributor authorHosseini, Ali
    contributor authorGadikota, Hemanth
    contributor authorGill, Thomas
    date accessioned2019-02-28T11:04:50Z
    date available2019-02-28T11:04:50Z
    date copyright11/22/2017 12:00:00 AM
    date issued2018
    identifier issn1932-6181
    identifier othermed_012_01_011004.pdf
    identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4252460
    description abstractThis study evaluated the biomechanical efficacy of single-tunnel double-bundle anterior cruciate ligament (ACL) reconstruction technique. The graft construct is achieved using a novel fixation device that splits an ACL (SPACL) graft into two bundles, recreating the anteromedial (AM) and posterolateral (PL) bundles for ACL reconstruction. A pullout strength test of the SPACL was performed using a 7-mm bovine digital extensor tendon graft. The capability in restoration of knee kinematics after SPACL reconstruction was investigated using cadaveric human knees on a robotic testing system under an anterior tibial load of 134 N and a simulated quadriceps load of 400 N. The data indicated that the SPACL graft has a pullout strength of 823.7±172.3 N. Under the 134 N anterior tibial load, the anteroposterior joint laxity had increased constraint using the SPACL reconstruction but not significantly (p > 0.05) at all selected flexion angles. Under the 400 N quadriceps load, no significant differences were observed between the anterior tibial translation of intact knee and SPACL conditions at all selected flexion angles, but the SPACL graft induced a significant increase in external tibial rotation compared to the intact knee condition at all selected flexion angles with a maximal external rotation of −3.20 deg ±3.6 deg at 90 deg flexion. These data showed that the SPACL technique is equivalent or superior to existing ACL reconstruction techniques in restoration of knee laxity and kinematics. The new SPACL reconstruction technique could provide a valuable alternation to contemporary ACL reconstruction surgery by more closely recreating native ACL kinematics.
    publisherThe American Society of Mechanical Engineers (ASME)
    titleA Novel Graft Fixation Technique for Anterior Cruciate Ligament Reconstruction Using Hamstring Tendon Grafts
    typeJournal Paper
    journal volume12
    journal issue1
    journal titleJournal of Medical Devices
    identifier doi10.1115/1.4038307
    journal fristpage11004
    journal lastpage011004-6
    treeJournal of Medical Devices:;2018:;volume( 012 ):;issue: 001
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian