    Improved Quantification of Exergy Destruction in Mechanical Cooling Tower Considering All Tower Inlet Parameters

    Source: Journal of Heat Transfer:;2018:;volume( 140 ):;issue: 005::page 52002
    Author:
    Singh, Kuljeet
    ,
    Das, Ranjan
    DOI: 10.1115/1.4038479
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: The present work establishes an improved experimentally validated analysis to predict performance and exergy-related parameters of a mechanical draft cooling tower involving wooden splash fills. Unlike earlier studies, which accounted for the effect of at most three tower inlet parameters for the exergy analysis, the present study simultaneously considers all five inlet parameters affecting the tower exergy performance. To simultaneously predict outlet air and water conditions, an optimization algorithm involving discrete functions of dry- and wet-bulb temperatures is used in conjunction with the mathematical model derived from mass and energy conservations within the control volume involving Bosnjakovic correlation. From practical point of view, five inlet parameters such as dry-bulb temperature, relative humidity, water temperature, water, and air flow rates are selected for the exergy analysis. Thereafter, the influence of all inlet parameters on the tower performance is analyzed on various important exergy-related factors. The quantitative analysis reveals that the inlet air humidity, water inlet temperature, and the inlet water mass flow rate significantly influence the air and water exergy changes. The present study also reveals that among the five inlet parameters, the water temperature, air humidity, and air mass flow rate are primarily responsible for the exergy destruction. Furthermore, it is observed that the second law efficiency is mainly governed by the inlet air flow rate. The present study is proposed to be useful for selecting the tower inlet parameters to improve exergy performance of mechanical cooling towers.
    • Download: (2.662Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      Improved Quantification of Exergy Destruction in Mechanical Cooling Tower Considering All Tower Inlet Parameters

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4251844
    Collections
    • Journal of Heat Transfer

    Show full item record

    contributor authorSingh, Kuljeet
    contributor authorDas, Ranjan
    date accessioned2019-02-28T11:01:32Z
    date available2019-02-28T11:01:32Z
    date copyright1/23/2018 12:00:00 AM
    date issued2018
    identifier issn0022-1481
    identifier otherht_140_05_052002.pdf
    identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4251844
    description abstractThe present work establishes an improved experimentally validated analysis to predict performance and exergy-related parameters of a mechanical draft cooling tower involving wooden splash fills. Unlike earlier studies, which accounted for the effect of at most three tower inlet parameters for the exergy analysis, the present study simultaneously considers all five inlet parameters affecting the tower exergy performance. To simultaneously predict outlet air and water conditions, an optimization algorithm involving discrete functions of dry- and wet-bulb temperatures is used in conjunction with the mathematical model derived from mass and energy conservations within the control volume involving Bosnjakovic correlation. From practical point of view, five inlet parameters such as dry-bulb temperature, relative humidity, water temperature, water, and air flow rates are selected for the exergy analysis. Thereafter, the influence of all inlet parameters on the tower performance is analyzed on various important exergy-related factors. The quantitative analysis reveals that the inlet air humidity, water inlet temperature, and the inlet water mass flow rate significantly influence the air and water exergy changes. The present study also reveals that among the five inlet parameters, the water temperature, air humidity, and air mass flow rate are primarily responsible for the exergy destruction. Furthermore, it is observed that the second law efficiency is mainly governed by the inlet air flow rate. The present study is proposed to be useful for selecting the tower inlet parameters to improve exergy performance of mechanical cooling towers.
    publisherThe American Society of Mechanical Engineers (ASME)
    titleImproved Quantification of Exergy Destruction in Mechanical Cooling Tower Considering All Tower Inlet Parameters
    typeJournal Paper
    journal volume140
    journal issue5
    journal titleJournal of Heat Transfer
    identifier doi10.1115/1.4038479
    journal fristpage52002
    journal lastpage052002-14
    treeJournal of Heat Transfer:;2018:;volume( 140 ):;issue: 005
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian