    Effects of Hydrophilic and Hydrophobic Surfaces on Start-Up Performance of an Oscillating Heat Pipe

    Source: Journal of Heat Transfer:;2018:;volume( 140 ):;issue: 001::page 12002
    Author:
    Hao, Tingting
    ,
    Ma, Xuehu
    ,
    Lan, Zhong
    DOI: 10.1115/1.4037341
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: Slug oscillations and heat transfer performance in the start-up stage of oscillating heat pipes (OHPs) with different surface wetting characteristics were investigated experimentally. The inner surfaces of the OHPs were superhydrophilic surface, hydrophilic surface, copper, hydrophobic surface, and superhydrophobic surface, respectively. There was a thin liquid film between the vapor bubble and the surface in the hydrophilic OHP which was different from hydrophobic OHP. Results showed that start-up performance was improved in hydrophilic OHP due to the low flow resistance and deteriorated in hydrophobic OHP as opposed to the copper OHP. Heat transfer results showed that wall temperature fluctuations were observed at the start-up stage. Compared with the copper OHP, start-up time and start-up temperature were reduced by 100 s and 3.32–4.41 °C in the hydrophilic OHP at the start-up stage. Slug oscillation frequency and temperature oscillation amplitude increased with heat input; however, slug oscillation amplitude increased first and then decreased with heat input. Compared with the copper OHP, with the increasing of 0–57% in slug oscillation amplitude and 0–100% in slug oscillation frequency, the thermal performance was enhanced by 0–67% in the hydrophilic OHP. Although the slug oscillation frequency in the superhydrophobic OHP was higher than that in the copper OHP, with the decreasing of 0–70% in the slug oscillation amplitude, the thermal resistance in superhydrophobic OHP was significantly increased and was 1.5–5 times higher than that in the copper OHP.
    • Download: (3.689Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      Effects of Hydrophilic and Hydrophobic Surfaces on Start-Up Performance of an Oscillating Heat Pipe

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4251714
    Collections
    • Journal of Heat Transfer

    Show full item record

    contributor authorHao, Tingting
    contributor authorMa, Xuehu
    contributor authorLan, Zhong
    date accessioned2019-02-28T11:00:47Z
    date available2019-02-28T11:00:47Z
    date copyright8/16/2017 12:00:00 AM
    date issued2018
    identifier issn0022-1481
    identifier otherht_140_01_012002.pdf
    identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4251714
    description abstractSlug oscillations and heat transfer performance in the start-up stage of oscillating heat pipes (OHPs) with different surface wetting characteristics were investigated experimentally. The inner surfaces of the OHPs were superhydrophilic surface, hydrophilic surface, copper, hydrophobic surface, and superhydrophobic surface, respectively. There was a thin liquid film between the vapor bubble and the surface in the hydrophilic OHP which was different from hydrophobic OHP. Results showed that start-up performance was improved in hydrophilic OHP due to the low flow resistance and deteriorated in hydrophobic OHP as opposed to the copper OHP. Heat transfer results showed that wall temperature fluctuations were observed at the start-up stage. Compared with the copper OHP, start-up time and start-up temperature were reduced by 100 s and 3.32–4.41 °C in the hydrophilic OHP at the start-up stage. Slug oscillation frequency and temperature oscillation amplitude increased with heat input; however, slug oscillation amplitude increased first and then decreased with heat input. Compared with the copper OHP, with the increasing of 0–57% in slug oscillation amplitude and 0–100% in slug oscillation frequency, the thermal performance was enhanced by 0–67% in the hydrophilic OHP. Although the slug oscillation frequency in the superhydrophobic OHP was higher than that in the copper OHP, with the decreasing of 0–70% in the slug oscillation amplitude, the thermal resistance in superhydrophobic OHP was significantly increased and was 1.5–5 times higher than that in the copper OHP.
    publisherThe American Society of Mechanical Engineers (ASME)
    titleEffects of Hydrophilic and Hydrophobic Surfaces on Start-Up Performance of an Oscillating Heat Pipe
    typeJournal Paper
    journal volume140
    journal issue1
    journal titleJournal of Heat Transfer
    identifier doi10.1115/1.4037341
    journal fristpage12002
    journal lastpage012002-9
    treeJournal of Heat Transfer:;2018:;volume( 140 ):;issue: 001
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian