Numerical Investigation on Film Cooling Performance of Fusiform Diffusion HolesSource: Journal of Heat Transfer:;2018:;volume( 140 ):;issue: 012::page 122201DOI: 10.1115/1.4041047Publisher: The American Society of Mechanical Engineers (ASME)
Abstract: This paper presents a numerical investigation of the film-cooling performance of a kind of diffusion hole with a fusiform cross section. Relative to the rectangular diffusion hole, the up- and/or downstream wall of the fusiform diffusion hole is outer convex. Under the same metering section area, six fusiform diffusion holes were divided into two groups with cross-sectional widths of W = 1.7D and W = 2.0D, respectively. Three fusiform cross section shapes in each group included only downstream wall outer convex, only upstream wall outer convex, or a combination of both. Simulations were performed in a flat plate model using a 3D steady computational fluid dynamics method under an engine-representative condition. The simulation results showed that the fusiform diffusion hole with only an outer convex upstream wall migrates the coolant laterally toward the hole centerline, and then forms or enhances a tripeak effectiveness pattern. Conversely, the fusiform diffusion hole with an outer convex downstream wall intensely expands the coolant to the hole two sides, and results in a bipeak effectiveness pattern, regardless of the upstream wall shape. Compared with the rectangular diffusion holes, the fusiform diffusion holes with only an upstream wall outer convex significantly increase the overall effectiveness at high blowing ratios. The increased magnitude is approximately 20% for the hole of W = 1.7D at M = 2.5. Besides, the fusiform diffusion holes with an outer convex upstream wall increase the discharge coefficient about 5%, within the moderate to high blowing ratio range.
|
Collections
Show full item record
contributor author | An, Bai-Tao | |
contributor author | Liu, Jian-Jun | |
date accessioned | 2019-02-28T11:00:24Z | |
date available | 2019-02-28T11:00:24Z | |
date copyright | 8/28/2018 12:00:00 AM | |
date issued | 2018 | |
identifier issn | 0022-1481 | |
identifier other | ht_140_12_122201.pdf | |
identifier uri | http://yetl.yabesh.ir/yetl1/handle/yetl/4251647 | |
description abstract | This paper presents a numerical investigation of the film-cooling performance of a kind of diffusion hole with a fusiform cross section. Relative to the rectangular diffusion hole, the up- and/or downstream wall of the fusiform diffusion hole is outer convex. Under the same metering section area, six fusiform diffusion holes were divided into two groups with cross-sectional widths of W = 1.7D and W = 2.0D, respectively. Three fusiform cross section shapes in each group included only downstream wall outer convex, only upstream wall outer convex, or a combination of both. Simulations were performed in a flat plate model using a 3D steady computational fluid dynamics method under an engine-representative condition. The simulation results showed that the fusiform diffusion hole with only an outer convex upstream wall migrates the coolant laterally toward the hole centerline, and then forms or enhances a tripeak effectiveness pattern. Conversely, the fusiform diffusion hole with an outer convex downstream wall intensely expands the coolant to the hole two sides, and results in a bipeak effectiveness pattern, regardless of the upstream wall shape. Compared with the rectangular diffusion holes, the fusiform diffusion holes with only an upstream wall outer convex significantly increase the overall effectiveness at high blowing ratios. The increased magnitude is approximately 20% for the hole of W = 1.7D at M = 2.5. Besides, the fusiform diffusion holes with an outer convex upstream wall increase the discharge coefficient about 5%, within the moderate to high blowing ratio range. | |
publisher | The American Society of Mechanical Engineers (ASME) | |
title | Numerical Investigation on Film Cooling Performance of Fusiform Diffusion Holes | |
type | Journal Paper | |
journal volume | 140 | |
journal issue | 12 | |
journal title | Journal of Heat Transfer | |
identifier doi | 10.1115/1.4041047 | |
journal fristpage | 122201 | |
journal lastpage | 122201-11 | |
tree | Journal of Heat Transfer:;2018:;volume( 140 ):;issue: 012 | |
contenttype | Fulltext |