    Assessment of RELAP5/MOD3.3 Against Single Rod Reflooding Experiments

    Source: ASCE-ASME Journal of Risk and Uncertainty in Engineering Systems, Part B: Mechanical Engineering:;2018:;volume( 004 ):;issue:003::page 30903
    Author:
    Lymperea, N.
    ,
    Nikoglou, A.
    ,
    Hinis, E.
    DOI: 10.1115/1.4037879
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: This study presents an assessment of the RELAP5/MOD3.3 using the experimental work upon the rewetting mechanism of bottom flooding of a vertical annular water flow inside a channel enclosing concentrically a heated rod. The experiments have been carried out in the experimental rig 1 of the Nuclear Engineering Department of National Technical University of Athens (NTUA-NED-ER1) inside which the dry out and the rewetting process of a hot vertical rod can be simulated. Experiments have been conducted at atmospheric conditions with liquid coolant flow rate within the range of 0.008 and 0.050 kg·s−1 and two levels of subcooling 25 and 50 K. The initial average surface temperature of the rod for each experiment was set at approximately 823 K. The predicted rod surface temperatures during rewetting of the RELAP5/MOD3.3 calculations were compared against the experimental values. The results presented in this study show that RELAP5/MOD3.3 provides temperature estimations of the reflooding mechanism within acceptable marginal error. However, larger deviations between predicted and experimental values have been observed when subcooled water was used instead of saturated one.
    • Download: (1.194Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      Assessment of RELAP5/MOD3.3 Against Single Rod Reflooding Experiments

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4251642
    Collections
    • ASCE-ASME Journal of Risk and Uncertainty in Engineering Systems, Part B: Mechanical Engineering

    Show full item record

    contributor authorLymperea, N.
    contributor authorNikoglou, A.
    contributor authorHinis, E.
    date accessioned2019-02-28T11:00:22Z
    date available2019-02-28T11:00:22Z
    date copyright12/5/2017 12:00:00 AM
    date issued2018
    identifier issn2332-9017
    identifier otherrisk_004_03_030903.pdf
    identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4251642
    description abstractThis study presents an assessment of the RELAP5/MOD3.3 using the experimental work upon the rewetting mechanism of bottom flooding of a vertical annular water flow inside a channel enclosing concentrically a heated rod. The experiments have been carried out in the experimental rig 1 of the Nuclear Engineering Department of National Technical University of Athens (NTUA-NED-ER1) inside which the dry out and the rewetting process of a hot vertical rod can be simulated. Experiments have been conducted at atmospheric conditions with liquid coolant flow rate within the range of 0.008 and 0.050 kg·s−1 and two levels of subcooling 25 and 50 K. The initial average surface temperature of the rod for each experiment was set at approximately 823 K. The predicted rod surface temperatures during rewetting of the RELAP5/MOD3.3 calculations were compared against the experimental values. The results presented in this study show that RELAP5/MOD3.3 provides temperature estimations of the reflooding mechanism within acceptable marginal error. However, larger deviations between predicted and experimental values have been observed when subcooled water was used instead of saturated one.
    publisherThe American Society of Mechanical Engineers (ASME)
    titleAssessment of RELAP5/MOD3.3 Against Single Rod Reflooding Experiments
    typeJournal Paper
    journal volume4
    journal issue3
    journal titleASCE-ASME Journal of Risk and Uncertainty in Engineering Systems, Part B: Mechanical Engineering
    identifier doi10.1115/1.4037879
    journal fristpage30903
    journal lastpage030903-7
    treeASCE-ASME Journal of Risk and Uncertainty in Engineering Systems, Part B: Mechanical Engineering:;2018:;volume( 004 ):;issue:003
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian