    Parametric Study and Optimization of Flow Characteristics of Wire-Nonparallel Plate-Type Electrostatic Air Accelerators

    Source: Journal of Fluids Engineering:;2018:;volume( 140 ):;issue: 010::page 101105
    Author:
    Zhang, J. F.
    ,
    Wang, S.
    ,
    Li, H. Y.
    ,
    Qu, Z. G.
    DOI: 10.1115/1.4040016
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: Wire and nonparallel plate electrode-type electrostatic air accelerators have attracted significant interest. The physical process involved in using accelerators is complicated. Moreover, mechanisms are unclear, especially for accelerators with double- and multiwire electrodes. In this study, the two-dimensional (2D) model of a wire–nonparallel plate-type accelerator validated by experiments is established with a finite element method. Onset voltage, average current, and outlet average velocity are analyzed with respect to different parameters. Onset voltage is derived by the proposed quadratic regression extrapolation method. Moreover, current is affected by interference and discharge effects, while velocity is also influenced by the suction effect. For the single-wire electrode, high wind speed can be obtained by either increasing channel slope or placing the wire near the entry section. For the double-wire electrode, velocity can be further increased when one of the wires is placed near the inlet and the distance between the two wires is widened. Comparatively, the velocity of the three-wire electrode is higher with larger gaps between wires and stronger discharge effect. The highest velocity is obtained by the four-wire electrode. Comparisons indicate that higher velocity can be obtained with weaker interference effect, stronger suction effect, and intensified discharge effect. Optimum parameter combinations are considered by the Taguchi method. Consequently, velocity can be enhanced by more than 39% after optimization compared with the reference design.
    • Download: (2.827Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      Parametric Study and Optimization of Flow Characteristics of Wire-Nonparallel Plate-Type Electrostatic Air Accelerators

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4251624
    Collections
    • Journal of Fluids Engineering

    Show full item record

    contributor authorZhang, J. F.
    contributor authorWang, S.
    contributor authorLi, H. Y.
    contributor authorQu, Z. G.
    date accessioned2019-02-28T11:00:16Z
    date available2019-02-28T11:00:16Z
    date copyright5/10/2018 12:00:00 AM
    date issued2018
    identifier issn0098-2202
    identifier otherfe_140_10_101105.pdf
    identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4251624
    description abstractWire and nonparallel plate electrode-type electrostatic air accelerators have attracted significant interest. The physical process involved in using accelerators is complicated. Moreover, mechanisms are unclear, especially for accelerators with double- and multiwire electrodes. In this study, the two-dimensional (2D) model of a wire–nonparallel plate-type accelerator validated by experiments is established with a finite element method. Onset voltage, average current, and outlet average velocity are analyzed with respect to different parameters. Onset voltage is derived by the proposed quadratic regression extrapolation method. Moreover, current is affected by interference and discharge effects, while velocity is also influenced by the suction effect. For the single-wire electrode, high wind speed can be obtained by either increasing channel slope or placing the wire near the entry section. For the double-wire electrode, velocity can be further increased when one of the wires is placed near the inlet and the distance between the two wires is widened. Comparatively, the velocity of the three-wire electrode is higher with larger gaps between wires and stronger discharge effect. The highest velocity is obtained by the four-wire electrode. Comparisons indicate that higher velocity can be obtained with weaker interference effect, stronger suction effect, and intensified discharge effect. Optimum parameter combinations are considered by the Taguchi method. Consequently, velocity can be enhanced by more than 39% after optimization compared with the reference design.
    publisherThe American Society of Mechanical Engineers (ASME)
    titleParametric Study and Optimization of Flow Characteristics of Wire-Nonparallel Plate-Type Electrostatic Air Accelerators
    typeJournal Paper
    journal volume140
    journal issue10
    journal titleJournal of Fluids Engineering
    identifier doi10.1115/1.4040016
    journal fristpage101105
    journal lastpage101105-11
    treeJournal of Fluids Engineering:;2018:;volume( 140 ):;issue: 010
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian