    Transient Pressure Analysis of a Prototype Pump Turbine: Field Tests and Simulation

    Source: Journal of Fluids Engineering:;2018:;volume( 140 ):;issue: 007::page 71102
    Author:
    Hu, Jinhong
    ,
    Yang, Jiandong
    ,
    Zeng, Wei
    ,
    Yang, Jiebin
    DOI: 10.1115/1.4039258
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: The transient behaviors of a prototype pump turbine are very important to the safe operation of a pumped-storage power plant. This is because the water hammer pressure during transient events affects the pressure surges in the spiral case (SC) and the draft tube (DT). In addition, the transient pressure pulsations in the vaneless space (VL) are important in the evaluation of the life of the runner. Although several detailed studies have been conducted on the water hammer pressure of a hydropower plant, very few have considered the transient pressure pulsations that occur in the pump turbine. The objective of the present study was to determine the characteristics of the transient pressure pulsations of a 300-MW prototype Francis pump turbine during load rejection and power failure. For this purpose, the frequency features in the steady-state were first analyzed using fast Fourier transform. A Savitzky–Golay filter was then used to extract the water hammer pressure and pulsating pressure from the acquired raw pressure signals. Further, a one-dimensional (1D) method of characteristics (MOC) mathematical model of the pump-turbine was established and used to simulate the transient variations of the flow discharge during transient events, to enable the division of the transient operation conditions into several domains. Finally, the characteristics of the transient pressure pulsations in the SC, vaneless space, and DT were investigated in the time and frequency domains. This paper also discusses the causes of the pressure pulsations that occur under different modes of operation of a pump turbine.
    • Download: (3.100Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      Transient Pressure Analysis of a Prototype Pump Turbine: Field Tests and Simulation

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4251499
    Collections
    • Journal of Fluids Engineering

    Show full item record

    contributor authorHu, Jinhong
    contributor authorYang, Jiandong
    contributor authorZeng, Wei
    contributor authorYang, Jiebin
    date accessioned2019-02-28T10:59:31Z
    date available2019-02-28T10:59:31Z
    date copyright3/16/2018 12:00:00 AM
    date issued2018
    identifier issn0098-2202
    identifier otherfe_140_07_071102.pdf
    identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4251499
    description abstractThe transient behaviors of a prototype pump turbine are very important to the safe operation of a pumped-storage power plant. This is because the water hammer pressure during transient events affects the pressure surges in the spiral case (SC) and the draft tube (DT). In addition, the transient pressure pulsations in the vaneless space (VL) are important in the evaluation of the life of the runner. Although several detailed studies have been conducted on the water hammer pressure of a hydropower plant, very few have considered the transient pressure pulsations that occur in the pump turbine. The objective of the present study was to determine the characteristics of the transient pressure pulsations of a 300-MW prototype Francis pump turbine during load rejection and power failure. For this purpose, the frequency features in the steady-state were first analyzed using fast Fourier transform. A Savitzky–Golay filter was then used to extract the water hammer pressure and pulsating pressure from the acquired raw pressure signals. Further, a one-dimensional (1D) method of characteristics (MOC) mathematical model of the pump-turbine was established and used to simulate the transient variations of the flow discharge during transient events, to enable the division of the transient operation conditions into several domains. Finally, the characteristics of the transient pressure pulsations in the SC, vaneless space, and DT were investigated in the time and frequency domains. This paper also discusses the causes of the pressure pulsations that occur under different modes of operation of a pump turbine.
    publisherThe American Society of Mechanical Engineers (ASME)
    titleTransient Pressure Analysis of a Prototype Pump Turbine: Field Tests and Simulation
    typeJournal Paper
    journal volume140
    journal issue7
    journal titleJournal of Fluids Engineering
    identifier doi10.1115/1.4039258
    journal fristpage71102
    journal lastpage071102-10
    treeJournal of Fluids Engineering:;2018:;volume( 140 ):;issue: 007
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian