YaBeSH Engineering and Technology Library

    • Journals
    • PaperQuest
    • YSE Standards
    • YaBeSH
    • Login
    View Item 
    •   YE&T Library
    • ASME
    • Journal of Energy Resources Technology
    • View Item
    •   YE&T Library
    • ASME
    • Journal of Energy Resources Technology
    • View Item
    • All Fields
    • Source Title
    • Year
    • Publisher
    • Title
    • Subject
    • Author
    • DOI
    • ISBN
    Advanced Search
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Archive

    A Perspective Evaluation Methodology for Economic Feasibility of Low Temperature Sustainable Energy Source in Heating Mode Technology

    Source: Journal of Energy Resources Technology:;2018:;volume 140:;issue 002::page 20902
    Author:
    Tarrad, Ali H.
    DOI: 10.1115/1.4037900
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: The economical and clean environment issues for a sustainable energy source at low temperature (LT) were considered and compared to natural gas technology as a fossil fuel source. The friendly environment refrigerants R410A, R407C, R717, R134a, and R600a were analyzed in an approximately 500 kW heating load output cascade heat pump. The heat pump was investigated at an intermediate temperature of 35 °C, high temperature (HT) cycle condenser at 70 °C, and compressors isentropic efficiency of 70%. All analyzed refrigerant pairs exhibited high heating season performance factor (HSPF), and it was ranged between 7 and 8.5. The thermal performance comparison revealed that the HSPF for R717/R600a showed the highest values among other refrigerant pairs. The results showed that at LT cycle evaporator temperature range of −10 to −2 °C, the natural gas technology revealed a higher season heating cost values than that of the heat pump plant by up to 10%. On the contrary at lower LT evaporator temperature, the heat pump plant technology exhibited a higher season heating cost lied in the range of 4–13.6% than that of the natural gas system. At compressors isentropic efficiency of 90%, the seasonal heating cost of the heat pump plant was lower than that of the natural gas technology by the range of 9–25% at test conditions. The mean seasonal CO2 amount released by the natural gas firing technology from all tested refrigerant pairs ranged between 2.1 and 2.5 times that of the heat pump plant technology for the investigated LT evaporator temperature range.
    • Download: (2.547Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      A Perspective Evaluation Methodology for Economic Feasibility of Low Temperature Sustainable Energy Source in Heating Mode Technology

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4250974
    Collections
    • Journal of Energy Resources Technology

    Show full item record

    contributor authorTarrad, Ali H.
    date accessioned2019-02-28T10:56:16Z
    date available2019-02-28T10:56:16Z
    date copyright10/4/2017 12:00:00 AM
    date issued2018
    identifier issn0195-0738
    identifier otherjert_140_02_020902.pdf
    identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4250974
    description abstractThe economical and clean environment issues for a sustainable energy source at low temperature (LT) were considered and compared to natural gas technology as a fossil fuel source. The friendly environment refrigerants R410A, R407C, R717, R134a, and R600a were analyzed in an approximately 500 kW heating load output cascade heat pump. The heat pump was investigated at an intermediate temperature of 35 °C, high temperature (HT) cycle condenser at 70 °C, and compressors isentropic efficiency of 70%. All analyzed refrigerant pairs exhibited high heating season performance factor (HSPF), and it was ranged between 7 and 8.5. The thermal performance comparison revealed that the HSPF for R717/R600a showed the highest values among other refrigerant pairs. The results showed that at LT cycle evaporator temperature range of −10 to −2 °C, the natural gas technology revealed a higher season heating cost values than that of the heat pump plant by up to 10%. On the contrary at lower LT evaporator temperature, the heat pump plant technology exhibited a higher season heating cost lied in the range of 4–13.6% than that of the natural gas system. At compressors isentropic efficiency of 90%, the seasonal heating cost of the heat pump plant was lower than that of the natural gas technology by the range of 9–25% at test conditions. The mean seasonal CO2 amount released by the natural gas firing technology from all tested refrigerant pairs ranged between 2.1 and 2.5 times that of the heat pump plant technology for the investigated LT evaporator temperature range.
    publisherThe American Society of Mechanical Engineers (ASME)
    titleA Perspective Evaluation Methodology for Economic Feasibility of Low Temperature Sustainable Energy Source in Heating Mode Technology
    typeJournal Paper
    journal volume140
    journal issue2
    journal titleJournal of Energy Resources Technology
    identifier doi10.1115/1.4037900
    journal fristpage20902
    journal lastpage020902-10
    treeJournal of Energy Resources Technology:;2018:;volume 140:;issue 002
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian