Show simple item record

contributor authorWang, Bo
contributor authorZhang, Chi
contributor authorLin, Yuzhen
contributor authorHui, Xin
contributor authorLi, Jibao
date accessioned2017-11-25T07:21:21Z
date available2017-11-25T07:21:21Z
date copyright2016/16/8
date issued2017
identifier issn0742-4795
identifier othergtp_139_01_011501.pdf
identifier urihttp://138.201.223.254:8080/yetl1/handle/yetl/4237013
description abstractIn order to balance the low emission and wide stabilization for lean premixed prevaporized (LPP) combustion, the centrally staged layout is preferred in advanced aero-engine combustors. However, compared with the conventional combustor, it is more difficult for the centrally staged combustor to light up as the main stage air layer will prevent the pilot fuel droplets arriving at igniter tip. The goal of the present paper is to study the effect of the main stage air on the ignition of the centrally staged combustor. Two cases of the main swirler vane angle of the TeLESS-II combustor, 20 deg and 30 deg are researched. The ignition results at room inlet temperature and pressure show that the ignition performance of the 30 deg vane angle case is better than that of the 20 deg vane angle case. High-speed camera, planar laser induced fluorescence (PLIF), and computational fluids dynamics (CFD) are used to better understand the ignition results. The high-speed camera has recorded the ignition process, indicated that an initial kernel forms just adjacent the liner wall after the igniter is turned on, the kernel propagates along the radial direction to the combustor center and begins to grow into a big flame, and then it spreads to the exit of the pilot stage, and eventually stabilizes the flame. CFD of the cold flow field coupled with spray field is conducted. A verification of the CFD method has been applied with PLIF measurement, and the simulation results can qualitatively represent the experimental data in terms of fuel distribution. The CFD results show that the radial dimensions of the primary recirculation zone of the two cases are very similar, and the dominant cause of the different ignition results is the vapor distribution of the fuel. The concentration of kerosene vapor of the 30 deg vane angle case is much larger than that of the 20 deg vane angle case close to the igniter tip and along the propagation route of the kernel, therefore, the 30 deg vane angle case has a better ignition performance. For the consideration of the ignition performance, a larger main swirler vane angle of 30 deg is suggested for the better fuel distribution when designing a centrally staged combustor.
publisherThe American Society of Mechanical Engineers (ASME)
titleInfluence of Main Swirler Vane Angle on the Ignition Performance of TeLESS-II Combustor
typeJournal Paper
journal volume139
journal issue1
journal titleJournal of Engineering for Gas Turbines and Power
identifier doi10.1115/1.4034154
journal fristpage11501
journal lastpage011501-8
treeJournal of Engineering for Gas Turbines and Power:;2017:;volume( 139 ):;issue: 001
contenttypeFulltext