    Toward the Virtual Benchmarking of Pneumatic Ventricular Assist Devices: Application of a Novel Fluid–Structure Interaction-Based Strategy to the Penn State 12 cc Device

    Source: Journal of Biomechanical Engineering:;2017:;volume( 139 ):;issue: 008::page 81008
    Author:
    Caimi, Alessandro
    ,
    Sturla, Francesco
    ,
    Good, Bryan
    ,
    Vidotto, Marco
    ,
    De Ponti, Rachele
    ,
    Piatti, Filippo
    ,
    Manning, Keefe B.
    ,
    Redaelli, Alberto
    DOI: 10.1115/1.4036936
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: The pediatric use of pneumatic ventricular assist devices (VADs) as a bridge to heart transplant still suffers for short-term major complications such as bleeding and thromboembolism. Although numerical techniques are increasingly exploited to support the process of device optimization, an effective virtual benchmark is still lacking. Focusing on the 12 cc Penn State pneumatic VAD, we developed a novel fluid–structure interaction (FSI) model able to capture the device functioning, reproducing the mechanical interplay between the diaphragm, the blood chamber, and the pneumatic actuation. The FSI model included the diaphragm mechanical response from uniaxial tensile tests, realistic VAD pressure operative conditions from a dedicated mock loop system, and the behavior of VAD valves. Our FSI-based benchmark effectively captured the complexity of the diaphragm dynamics. During diastole, the initial slow diaphragm retraction in the air chamber was followed by a more rapid phase; asymmetries were noticed in the diaphragm configuration during its systolic inflation in the blood chamber. The FSI model also captured the major features of the device fluid dynamics. In particular, during diastole, a rotational wall washing pattern is promoted by the penetrating inlet jet with a low-velocity region located in the center of the device. Our numerical analysis of the 12 cc Penn State VAD points out the potential of the proposed FSI approach well resembling previous experimental evidences; if further tested and validated, it could be exploited as a virtual benchmark to deepen VAD-related complications and to support the ongoing optimization of pediatric devices.
    • Download: (5.423Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      Toward the Virtual Benchmarking of Pneumatic Ventricular Assist Devices: Application of a Novel Fluid–Structure Interaction-Based Strategy to the Penn State 12 cc Device

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4236086
    Collections
    • Journal of Biomechanical Engineering

    Show full item record

    contributor authorCaimi, Alessandro
    contributor authorSturla, Francesco
    contributor authorGood, Bryan
    contributor authorVidotto, Marco
    contributor authorDe Ponti, Rachele
    contributor authorPiatti, Filippo
    contributor authorManning, Keefe B.
    contributor authorRedaelli, Alberto
    date accessioned2017-11-25T07:19:53Z
    date available2017-11-25T07:19:53Z
    date copyright2017/16/6
    date issued2017
    identifier issn0148-0731
    identifier otherbio_139_08_081008.pdf
    identifier urihttp://138.201.223.254:8080/yetl1/handle/yetl/4236086
    description abstractThe pediatric use of pneumatic ventricular assist devices (VADs) as a bridge to heart transplant still suffers for short-term major complications such as bleeding and thromboembolism. Although numerical techniques are increasingly exploited to support the process of device optimization, an effective virtual benchmark is still lacking. Focusing on the 12 cc Penn State pneumatic VAD, we developed a novel fluid–structure interaction (FSI) model able to capture the device functioning, reproducing the mechanical interplay between the diaphragm, the blood chamber, and the pneumatic actuation. The FSI model included the diaphragm mechanical response from uniaxial tensile tests, realistic VAD pressure operative conditions from a dedicated mock loop system, and the behavior of VAD valves. Our FSI-based benchmark effectively captured the complexity of the diaphragm dynamics. During diastole, the initial slow diaphragm retraction in the air chamber was followed by a more rapid phase; asymmetries were noticed in the diaphragm configuration during its systolic inflation in the blood chamber. The FSI model also captured the major features of the device fluid dynamics. In particular, during diastole, a rotational wall washing pattern is promoted by the penetrating inlet jet with a low-velocity region located in the center of the device. Our numerical analysis of the 12 cc Penn State VAD points out the potential of the proposed FSI approach well resembling previous experimental evidences; if further tested and validated, it could be exploited as a virtual benchmark to deepen VAD-related complications and to support the ongoing optimization of pediatric devices.
    publisherThe American Society of Mechanical Engineers (ASME)
    titleToward the Virtual Benchmarking of Pneumatic Ventricular Assist Devices: Application of a Novel Fluid–Structure Interaction-Based Strategy to the Penn State 12 cc Device
    typeJournal Paper
    journal volume139
    journal issue8
    journal titleJournal of Biomechanical Engineering
    identifier doi10.1115/1.4036936
    journal fristpage81008
    journal lastpage081008-10
    treeJournal of Biomechanical Engineering:;2017:;volume( 139 ):;issue: 008
    contenttypeFulltext