YaBeSH Engineering and Technology Library

    • Journals
    • PaperQuest
    • YSE Standards
    • YaBeSH
    • Login
    View Item 
    •   YE&T Library
    • ASME
    • Journal of Biomechanical Engineering
    • View Item
    •   YE&T Library
    • ASME
    • Journal of Biomechanical Engineering
    • View Item
    • All Fields
    • Source Title
    • Year
    • Publisher
    • Title
    • Subject
    • Author
    • DOI
    • ISBN
    Advanced Search
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Archive

    Characterization and Correction of Errors in Computing Contact Location Between Curved Articular Surfaces: Application to Total Knee Arthroplasty

    Source: Journal of Biomechanical Engineering:;2017:;volume( 139 ):;issue: 006::page 61006
    Author:
    Roth, Joshua D.
    ,
    Howell, Stephen M.
    ,
    Hull, Maury L.
    DOI: 10.1115/1.4036147
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: In total knee arthroplasty (TKA), one common metric used to evaluate innovations in component designs, methods of component alignment, and surgical techniques aimed at decreasing the high rate of patient-reported dissatisfaction is tibiofemoral contact kinematics. Tibiofemoral contact kinematics are determined based on the movement of the contact locations in the medial and lateral compartments of the tibia during knee flexion. A tibial force sensor is a useful instrument to determine the contact locations, because it can simultaneously determine contact forces and contact locations. Previous reports of tibial force sensors have neither characterized nor corrected errors in the computed contact location (i.e., center of pressure) between the femoral and tibial components in TKA that, based on a static analysis, are caused by the curved articular surface of the tibial component. The objectives were to experimentally characterize these errors and to develop and validate an error correction algorithm. The errors were characterized by calculating the difference between the errors in the computed contact locations when forces were applied normal to the tibial articular surface and those when forces were applied normal to the tibial baseplate. The algorithm generated error correction functions to minimize these errors and was validated by determining how much the error correction functions reduced the errors in the computed contact location caused by the curved articular surface. The curved articular surface primarily caused bias (i.e., average or systematic error) which ranged from 1.0 to 2.7 mm in regions of high curvature. The error correction functions reduced the bias in these regions to negligible levels ranging from 0.0 to 0.6 mm (p < 0.001). Bias in the computed contact locations caused by the curved articular surface of the tibial component as small as 1 mm needs to be accounted for, because it might inflate the computed internal–external rotation and anterior–posterior translation of femur on the tibia leading to false identifications of clinically undesirable contact kinematics (e.g., internal rotation and anterior translation during flexion). Our novel error correction algorithm is an effective method to account for this bias to more accurately compute contact kinematics.
    • Download: (2.756Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      Characterization and Correction of Errors in Computing Contact Location Between Curved Articular Surfaces: Application to Total Knee Arthroplasty

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4235785
    Collections
    • Journal of Biomechanical Engineering

    Show full item record

    contributor authorRoth, Joshua D.
    contributor authorHowell, Stephen M.
    contributor authorHull, Maury L.
    date accessioned2017-11-25T07:19:23Z
    date available2017-11-25T07:19:23Z
    date copyright2017/26/4
    date issued2017
    identifier issn0148-0731
    identifier otherbio_139_06_061006.pdf
    identifier urihttp://138.201.223.254:8080/yetl1/handle/yetl/4235785
    description abstractIn total knee arthroplasty (TKA), one common metric used to evaluate innovations in component designs, methods of component alignment, and surgical techniques aimed at decreasing the high rate of patient-reported dissatisfaction is tibiofemoral contact kinematics. Tibiofemoral contact kinematics are determined based on the movement of the contact locations in the medial and lateral compartments of the tibia during knee flexion. A tibial force sensor is a useful instrument to determine the contact locations, because it can simultaneously determine contact forces and contact locations. Previous reports of tibial force sensors have neither characterized nor corrected errors in the computed contact location (i.e., center of pressure) between the femoral and tibial components in TKA that, based on a static analysis, are caused by the curved articular surface of the tibial component. The objectives were to experimentally characterize these errors and to develop and validate an error correction algorithm. The errors were characterized by calculating the difference between the errors in the computed contact locations when forces were applied normal to the tibial articular surface and those when forces were applied normal to the tibial baseplate. The algorithm generated error correction functions to minimize these errors and was validated by determining how much the error correction functions reduced the errors in the computed contact location caused by the curved articular surface. The curved articular surface primarily caused bias (i.e., average or systematic error) which ranged from 1.0 to 2.7 mm in regions of high curvature. The error correction functions reduced the bias in these regions to negligible levels ranging from 0.0 to 0.6 mm (p < 0.001). Bias in the computed contact locations caused by the curved articular surface of the tibial component as small as 1 mm needs to be accounted for, because it might inflate the computed internal–external rotation and anterior–posterior translation of femur on the tibia leading to false identifications of clinically undesirable contact kinematics (e.g., internal rotation and anterior translation during flexion). Our novel error correction algorithm is an effective method to account for this bias to more accurately compute contact kinematics.
    publisherThe American Society of Mechanical Engineers (ASME)
    titleCharacterization and Correction of Errors in Computing Contact Location Between Curved Articular Surfaces: Application to Total Knee Arthroplasty
    typeJournal Paper
    journal volume139
    journal issue6
    journal titleJournal of Biomechanical Engineering
    identifier doi10.1115/1.4036147
    journal fristpage61006
    journal lastpage061006-10
    treeJournal of Biomechanical Engineering:;2017:;volume( 139 ):;issue: 006
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian