    Investigation on Maximum Upsurge and Air Pressure of Air Cushion Surge Chamber in Hydropower Stations

    Source: Journal of Pressure Vessel Technology:;2017:;volume( 139 ):;issue: 003::page 31603
    Author:
    Liu, Jiachun
    ,
    Zhang, Jian
    ,
    Chen, Sheng
    ,
    Yu, Xiaodong
    DOI: 10.1115/1.4035790
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: The maximum upsurge (MU) and the maximum air chamber pressure (MACP) are critical parameters for the design of air cushion surge chamber (ACSC) in hydropower stations. In this paper, the existence of the MU and the MACP are proved under compound conditions. The theoretical formula predicting the most dangerous superposition moment of the MU and the MACP under compound condition is derived, and the influence factors are analyzed as well. To verify the accuracy of the formula, the rigid model based on Runge-Kutta method (RKM) and the elastic model based on the method of characteristics (MOC) are established, respectively, according to the parameters of the ACSC system in the practical hydropower station. The numerical results agree well with the theoretical predictions. In addition, the MU and the MACP under three control conditions are simulated, respectively, and the results show that when the cross-sectional area of throttled orifice is small, the MU and the MACP occur under the successive load rejection condition (SLR); when the cross-sectional area is large, the MU and the MACP occur under the load rejection after load acceptance condition (LRLA).
    • Download: (508.3Kb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      Investigation on Maximum Upsurge and Air Pressure of Air Cushion Surge Chamber in Hydropower Stations

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4235595
    Collections
    • Journal of Pressure Vessel Technology

    Show full item record

    contributor authorLiu, Jiachun
    contributor authorZhang, Jian
    contributor authorChen, Sheng
    contributor authorYu, Xiaodong
    date accessioned2017-11-25T07:19:06Z
    date available2017-11-25T07:19:06Z
    date copyright2017/8/2
    date issued2017
    identifier issn0094-9930
    identifier otherpvt_139_03_031603.pdf
    identifier urihttp://138.201.223.254:8080/yetl1/handle/yetl/4235595
    description abstractThe maximum upsurge (MU) and the maximum air chamber pressure (MACP) are critical parameters for the design of air cushion surge chamber (ACSC) in hydropower stations. In this paper, the existence of the MU and the MACP are proved under compound conditions. The theoretical formula predicting the most dangerous superposition moment of the MU and the MACP under compound condition is derived, and the influence factors are analyzed as well. To verify the accuracy of the formula, the rigid model based on Runge-Kutta method (RKM) and the elastic model based on the method of characteristics (MOC) are established, respectively, according to the parameters of the ACSC system in the practical hydropower station. The numerical results agree well with the theoretical predictions. In addition, the MU and the MACP under three control conditions are simulated, respectively, and the results show that when the cross-sectional area of throttled orifice is small, the MU and the MACP occur under the successive load rejection condition (SLR); when the cross-sectional area is large, the MU and the MACP occur under the load rejection after load acceptance condition (LRLA).
    publisherThe American Society of Mechanical Engineers (ASME)
    titleInvestigation on Maximum Upsurge and Air Pressure of Air Cushion Surge Chamber in Hydropower Stations
    typeJournal Paper
    journal volume139
    journal issue3
    journal titleJournal of Pressure Vessel Technology
    identifier doi10.1115/1.4035790
    journal fristpage31603
    journal lastpage031603-8
    treeJournal of Pressure Vessel Technology:;2017:;volume( 139 ):;issue: 003
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian