    Evaluation of Hemodynamics in a Prestressed and Compliant Tapered Femoral Artery Using an Optimization-Based Inverse Algorithm

    Source: Journal of Biomechanical Engineering:;2017:;volume( 139 ):;issue: 004::page 41002
    Author:
    Banerjee, Rupak K.
    ,
    D'Souza, Gavin A.
    ,
    Paul, Anup K.
    ,
    Das, Ashish
    DOI: 10.1115/1.4035916
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: The important factors that affect the arterial wall compliance are the tissue properties of the arterial wall, the in vivo pulsatile pressure, and the prestressed condition of the artery. It is necessary to obtain the load-free geometry for determining the physiological level of prestress in the arterial wall. The previously developed optimization-based inverse algorithm was improved to obtain the load-free geometry and the wall prestress of an idealized tapered femoral artery of a dog under varying arterial wall properties. The compliance of the artery was also evaluated over a range of systemic pressures (72.5–140.7 mmHg), associated blood flows, and artery wall properties using the prestressed arterial geometry. The results showed that the computed load-free outer diameter at the inlet of the tapered artery was 6.7%, 9.0%, and 12% smaller than the corresponding in vivo diameter for the 25% softer, baseline, and 25% stiffer arterial wall properties, respectively. In contrast, the variations in the prestressed geometry and circumferential wall prestress were less than 2% for variable arterial wall properties. The computed compliance at the inlet of the prestressed artery for the baseline arterial wall property was 0.34%, 0.19%, and 0.13% diameter change/mmHg for time-averaged pressures of 72.5, 104.1, and 140.7 mmHg, respectively. However, the variation in compliance due to the change in arterial wall property was less than 6%. The load-free and prestressed geometries of the idealized tapered femoral artery were accurately (error within 1.2% of the in vivo geometry) computed under variable arterial wall properties using the modified inverse algorithm. Based on the blood-arterial wall interaction results, the arterial wall compliance was influenced significantly by the change in average pressure. In contrast, the change in arterial wall property did not influence the arterial wall compliance.
    • Download: (2.355Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      Evaluation of Hemodynamics in a Prestressed and Compliant Tapered Femoral Artery Using an Optimization-Based Inverse Algorithm

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4235530
    Collections
    • Journal of Biomechanical Engineering

    Show full item record

    contributor authorBanerjee, Rupak K.
    contributor authorD'Souza, Gavin A.
    contributor authorPaul, Anup K.
    contributor authorDas, Ashish
    date accessioned2017-11-25T07:19:01Z
    date available2017-11-25T07:19:01Z
    date copyright2017/23/2
    date issued2017
    identifier issn0148-0731
    identifier otherbio_139_04_041002.pdf
    identifier urihttp://138.201.223.254:8080/yetl1/handle/yetl/4235530
    description abstractThe important factors that affect the arterial wall compliance are the tissue properties of the arterial wall, the in vivo pulsatile pressure, and the prestressed condition of the artery. It is necessary to obtain the load-free geometry for determining the physiological level of prestress in the arterial wall. The previously developed optimization-based inverse algorithm was improved to obtain the load-free geometry and the wall prestress of an idealized tapered femoral artery of a dog under varying arterial wall properties. The compliance of the artery was also evaluated over a range of systemic pressures (72.5–140.7 mmHg), associated blood flows, and artery wall properties using the prestressed arterial geometry. The results showed that the computed load-free outer diameter at the inlet of the tapered artery was 6.7%, 9.0%, and 12% smaller than the corresponding in vivo diameter for the 25% softer, baseline, and 25% stiffer arterial wall properties, respectively. In contrast, the variations in the prestressed geometry and circumferential wall prestress were less than 2% for variable arterial wall properties. The computed compliance at the inlet of the prestressed artery for the baseline arterial wall property was 0.34%, 0.19%, and 0.13% diameter change/mmHg for time-averaged pressures of 72.5, 104.1, and 140.7 mmHg, respectively. However, the variation in compliance due to the change in arterial wall property was less than 6%. The load-free and prestressed geometries of the idealized tapered femoral artery were accurately (error within 1.2% of the in vivo geometry) computed under variable arterial wall properties using the modified inverse algorithm. Based on the blood-arterial wall interaction results, the arterial wall compliance was influenced significantly by the change in average pressure. In contrast, the change in arterial wall property did not influence the arterial wall compliance.
    publisherThe American Society of Mechanical Engineers (ASME)
    titleEvaluation of Hemodynamics in a Prestressed and Compliant Tapered Femoral Artery Using an Optimization-Based Inverse Algorithm
    typeJournal Paper
    journal volume139
    journal issue4
    journal titleJournal of Biomechanical Engineering
    identifier doi10.1115/1.4035916
    journal fristpage41002
    journal lastpage041002-11
    treeJournal of Biomechanical Engineering:;2017:;volume( 139 ):;issue: 004
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian