    Study of Cholesterol Repletion Effect on Nanomechanical Properties of Human Umbilical Vein Endothelial Cell Via Rapid Broadband Atomic Force Microscopy

    Source: Journal of Biomechanical Engineering:;2017:;volume( 139 ):;issue: 003::page 34501
    Author:
    Yan, Bo
    ,
    Ren, Juan
    ,
    Liu, Yue
    ,
    Huang, Huarong
    ,
    Zheng, Xi
    ,
    Zou, Qingze
    DOI: 10.1115/1.4035260
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: Abnormalities of blood cholesterol concentration are associated with increased risks for vascular disease, especially heart attacks and strokes. As one of the main lipid components of plasma membrane in all mammalian cells, cholesterol has a major impact on the mechanical properties of the membrane of endothelial cells. Although the effect of cholesterol depletion on cell mechanical properties has been studied, no results yet have been reported on quantitative investigation of cholesterol repletion effect. In this study, the cholesterol repletion effect on the nanomechanical properties of human umbilical vein endothelial cell (EA.hy926) was studied using a control-based atomic force microscope (AFM) nanomechanical measurement protocol. The viscoelasticity of EA.hy926 cells were measured over a large frequency range (0.1–100 Hz) using both constant-rate excitation force with different loading rates and a broadband excitation force. The viscoelasticity oscillation of the cell membranes under the cholesterol effect was also monitored in real-time. The experiment results showed that under the effect of cholesterol repletion, both the Young's modulus and the complex modulus of EA.hy926 cell were increased over 30%, respectively, and moreover, the amplitudes of both the elasticity oscillation and the viscosity oscillation at a period of around 200 s were increased over 70%, respectively. Therefore, this work is among the first to investigate the mechanical properties, particularly, the broadband viscoelasticity variations of EA.hy926 cells under cholesterol repletion treatment. The results revealed that cholesterol repletion may reinforce the coupling of F-actin to plasma membrane by increasing actin stability, and the cholesterol might have modified the submembrane cytoskeletal organization of EA.hy926 cell by causing the involvement of the motor protein nonmuscle myosin II.
    • Download: (1.383Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      Study of Cholesterol Repletion Effect on Nanomechanical Properties of Human Umbilical Vein Endothelial Cell Via Rapid Broadband Atomic Force Microscopy

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4235497
    Collections
    • Journal of Biomechanical Engineering

    Show full item record

    contributor authorYan, Bo
    contributor authorRen, Juan
    contributor authorLiu, Yue
    contributor authorHuang, Huarong
    contributor authorZheng, Xi
    contributor authorZou, Qingze
    date accessioned2017-11-25T07:18:56Z
    date available2017-11-25T07:18:56Z
    date copyright2017/23/1
    date issued2017
    identifier issn0148-0731
    identifier otherbio_139_03_034501.pdf
    identifier urihttp://138.201.223.254:8080/yetl1/handle/yetl/4235497
    description abstractAbnormalities of blood cholesterol concentration are associated with increased risks for vascular disease, especially heart attacks and strokes. As one of the main lipid components of plasma membrane in all mammalian cells, cholesterol has a major impact on the mechanical properties of the membrane of endothelial cells. Although the effect of cholesterol depletion on cell mechanical properties has been studied, no results yet have been reported on quantitative investigation of cholesterol repletion effect. In this study, the cholesterol repletion effect on the nanomechanical properties of human umbilical vein endothelial cell (EA.hy926) was studied using a control-based atomic force microscope (AFM) nanomechanical measurement protocol. The viscoelasticity of EA.hy926 cells were measured over a large frequency range (0.1–100 Hz) using both constant-rate excitation force with different loading rates and a broadband excitation force. The viscoelasticity oscillation of the cell membranes under the cholesterol effect was also monitored in real-time. The experiment results showed that under the effect of cholesterol repletion, both the Young's modulus and the complex modulus of EA.hy926 cell were increased over 30%, respectively, and moreover, the amplitudes of both the elasticity oscillation and the viscosity oscillation at a period of around 200 s were increased over 70%, respectively. Therefore, this work is among the first to investigate the mechanical properties, particularly, the broadband viscoelasticity variations of EA.hy926 cells under cholesterol repletion treatment. The results revealed that cholesterol repletion may reinforce the coupling of F-actin to plasma membrane by increasing actin stability, and the cholesterol might have modified the submembrane cytoskeletal organization of EA.hy926 cell by causing the involvement of the motor protein nonmuscle myosin II.
    publisherThe American Society of Mechanical Engineers (ASME)
    titleStudy of Cholesterol Repletion Effect on Nanomechanical Properties of Human Umbilical Vein Endothelial Cell Via Rapid Broadband Atomic Force Microscopy
    typeJournal Paper
    journal volume139
    journal issue3
    journal titleJournal of Biomechanical Engineering
    identifier doi10.1115/1.4035260
    journal fristpage34501
    journal lastpage034501-5
    treeJournal of Biomechanical Engineering:;2017:;volume( 139 ):;issue: 003
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian