YaBeSH Engineering and Technology Library

    • Journals
    • PaperQuest
    • YSE Standards
    • YaBeSH
    • Login
    View Item 
    •   YE&T Library
    • ASME
    • Journal of Engineering Materials and Technology
    • View Item
    •   YE&T Library
    • ASME
    • Journal of Engineering Materials and Technology
    • View Item
    • All Fields
    • Source Title
    • Year
    • Publisher
    • Title
    • Subject
    • Author
    • DOI
    • ISBN
    Advanced Search
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Archive

    Diffusible Hydrogen Level in Deposited Metal and Their Effect on Tensile Properties and Flexural Strength of P91 Steel

    Source: Journal of Engineering Materials and Technology:;2017:;volume( 139 ):;issue: 003::page 31004
    Author:
    Pandey, Chandan
    ,
    Mahapatra, M. M.
    ,
    Kumar, Pradeep
    ,
    Saini, N.
    DOI: 10.1115/1.4035764
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: In a “very high-temperature reactor” (VHTR), the Nb–V-modified 9Cr–1Mo creep strength enhance the ferritic (CSEF) steel which is the chosen material for fabrication of reactor pressure vessels and piping because of its excellent high temperature thermal and mechanical properties. In such CSEF steel weldments, the hydrogen-induced cracking (HIC) is a critical issue. In the present work, the different levels of hydrogen have been induced in P91 CSEF weld metal to study their effect on HIC. The HIC susceptibility of P91 steel welds has been studied by carrying out the tensile test and flexural test for the different level of diffusible hydrogen. The hydrogen levels in deposited metals have been measured by using the mercury method. The fracture tensile and flexural test samples have been characterized based on the field-emission scanning electron microscope (FE-SEM). It is concluded that higher the level of diffusible hydrogen in deposited metal, more is the susceptibility of P91 steel to HIC. The minimum flexural and tensile strength are 507.45 MPa and 282 MPa, respectively, for 12.54 ml volume of diffusible hydrogen in 100 g of deposited weld metal.
    • Download: (4.062Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      Diffusible Hydrogen Level in Deposited Metal and Their Effect on Tensile Properties and Flexural Strength of P91 Steel

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4233902
    Collections
    • Journal of Engineering Materials and Technology

    Show full item record

    contributor authorPandey, Chandan
    contributor authorMahapatra, M. M.
    contributor authorKumar, Pradeep
    contributor authorSaini, N.
    date accessioned2017-11-25T07:16:14Z
    date available2017-11-25T07:16:14Z
    date copyright2017/23/3
    date issued2017
    identifier issn0094-4289
    identifier othermats_139_03_031004.pdf
    identifier urihttp://138.201.223.254:8080/yetl1/handle/yetl/4233902
    description abstractIn a “very high-temperature reactor” (VHTR), the Nb–V-modified 9Cr–1Mo creep strength enhance the ferritic (CSEF) steel which is the chosen material for fabrication of reactor pressure vessels and piping because of its excellent high temperature thermal and mechanical properties. In such CSEF steel weldments, the hydrogen-induced cracking (HIC) is a critical issue. In the present work, the different levels of hydrogen have been induced in P91 CSEF weld metal to study their effect on HIC. The HIC susceptibility of P91 steel welds has been studied by carrying out the tensile test and flexural test for the different level of diffusible hydrogen. The hydrogen levels in deposited metals have been measured by using the mercury method. The fracture tensile and flexural test samples have been characterized based on the field-emission scanning electron microscope (FE-SEM). It is concluded that higher the level of diffusible hydrogen in deposited metal, more is the susceptibility of P91 steel to HIC. The minimum flexural and tensile strength are 507.45 MPa and 282 MPa, respectively, for 12.54 ml volume of diffusible hydrogen in 100 g of deposited weld metal.
    publisherThe American Society of Mechanical Engineers (ASME)
    titleDiffusible Hydrogen Level in Deposited Metal and Their Effect on Tensile Properties and Flexural Strength of P91 Steel
    typeJournal Paper
    journal volume139
    journal issue3
    journal titleJournal of Engineering Materials and Technology
    identifier doi10.1115/1.4035764
    journal fristpage31004
    journal lastpage031004-11
    treeJournal of Engineering Materials and Technology:;2017:;volume( 139 ):;issue: 003
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian