description abstractMeasurements are presented for a high-pressure transonic turbine stage operating at design-corrected conditions with forward and aft purge flow and blade film cooling in a short-duration blowdown facility. Four different film-cooling configurations are investigated: simple cylindrical-shaped holes, diffusing fan-shaped holes, an advanced-shaped hole, and uncooled blades. A rainbow turbine approach is used so each of the four blade types comprises a wedge of the overall bladed disk and is investigated simultaneously at identical speed and vane exit conditions. Double-sided Kapton heat-flux gauges are installed at midspan on all three film-cooled blade types, and single-sided Pyrex heat-flux gauges are installed on the uncooled blades. Kulite pressure transducers are installed at midspan on cooled blades with round and fan-shaped cooling holes. Experimental results are presented both as time-averaged values and as time-accurate ensemble-averages. In addition, the results of a steady Reynolds-averaged Navier–Stokes computational fluid dynamics (RANS CFD) computation are compared to the time-averaged data. The computational and experimental results show that the cooled blades reduce heat transfer into the blade significantly from the uncooled case, but the overall differences in heat transfer among the three cooling configurations are small. This challenges previous conclusions for simplified geometries that show shaped cooling holes outperforming cylindrical holes by a great margin. It suggests that the more complicated flow physics associated with an airfoil operating in an engine-representative environment reduces the effectiveness of the shaped cooling holes. Time-accurate comparisons provide some insight into the complicated interactions that are driving these flows and make it difficult to characterize cooling benefits.
publisherThe American Society of Mechanical Engineers (ASME)
titleUnsteady Heat Transfer and Pressure Measurements on the Airfoils of a Rotating Transonic Turbine With Multiple Cooling Configurations
typeJournal Paper
journal volume139
journal issue9
journal titleJournal of Engineering for Gas Turbines and Power
identifier doi10.1115/1.4036059
journal fristpage92601
journal lastpage092601-10
treeJournal of Engineering for Gas Turbines and Power:;2017:;volume( 139 ):;issue: 009