    Wind Tunnel Experiment for Predicting a Visible Plume Region from a Nuclear Power Plant Cooling Tower

    Source: Journal of Applied Meteorology and Climatology:;2013:;volume( 053 ):;issue: 002::page 234
    Author:
    Guo, Dong-Peng
    ,
    Yao, Ren-Tai
    ,
    Fan, Dan
    DOI: 10.1175/JAMC-D-13-0153.1
    Publisher: American Meteorological Society
    Abstract: his paper introduces a wind tunnel experiment to study the effect of the cooling tower of a nuclear power plant on the flow and the characteristics of visible plume regions. The relevant characteristics of the flow field near the cooling tower, such as the plume rise and the visible plume region, are compared with the results of previous experimental data from Électricité de France (EDF) and the Briggs formulas. The results show that the wind tunnel experiment can simulate the top backflow of the cooling tower and the rear cavity regions among others. In the near-wake region, including the recirculation cavity, mean velocity decreases and turbulence intensity increases significantly. The maximum turbulence intensity observed is 0.5. In addition, the disturbed flow extent of the cooling tower top reaches 1.5 times the cooling tower height. Analysis of the visible plume region shows that the wind tunnel experiment can simulate the variation of a visible plume region. The results are consistent with the wind tunnel experiment of EDF. Moreover, the plume rise analysis shows that the wind tunnel experiment data are in agreement with the Briggs formulas for 50?200 m. As a whole, the proposed wind tunnel experiment can simulate the flow field variation of the visible plume region and the plume rise around the buildings with reasonable accuracy.
    • Download: (1010.Kb)
    • Show Full MetaData Hide Full MetaData
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      Wind Tunnel Experiment for Predicting a Visible Plume Region from a Nuclear Power Plant Cooling Tower

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4217158
    Collections
    • Journal of Applied Meteorology and Climatology

    Show full item record

    contributor authorGuo, Dong-Peng
    contributor authorYao, Ren-Tai
    contributor authorFan, Dan
    date accessioned2017-06-09T16:49:47Z
    date available2017-06-09T16:49:47Z
    date copyright2014/02/01
    date issued2013
    identifier issn1558-8424
    identifier otherams-74884.pdf
    identifier urihttp://onlinelibrary.yabesh.ir/handle/yetl/4217158
    description abstracthis paper introduces a wind tunnel experiment to study the effect of the cooling tower of a nuclear power plant on the flow and the characteristics of visible plume regions. The relevant characteristics of the flow field near the cooling tower, such as the plume rise and the visible plume region, are compared with the results of previous experimental data from Électricité de France (EDF) and the Briggs formulas. The results show that the wind tunnel experiment can simulate the top backflow of the cooling tower and the rear cavity regions among others. In the near-wake region, including the recirculation cavity, mean velocity decreases and turbulence intensity increases significantly. The maximum turbulence intensity observed is 0.5. In addition, the disturbed flow extent of the cooling tower top reaches 1.5 times the cooling tower height. Analysis of the visible plume region shows that the wind tunnel experiment can simulate the variation of a visible plume region. The results are consistent with the wind tunnel experiment of EDF. Moreover, the plume rise analysis shows that the wind tunnel experiment data are in agreement with the Briggs formulas for 50?200 m. As a whole, the proposed wind tunnel experiment can simulate the flow field variation of the visible plume region and the plume rise around the buildings with reasonable accuracy.
    publisherAmerican Meteorological Society
    titleWind Tunnel Experiment for Predicting a Visible Plume Region from a Nuclear Power Plant Cooling Tower
    typeJournal Paper
    journal volume53
    journal issue2
    journal titleJournal of Applied Meteorology and Climatology
    identifier doi10.1175/JAMC-D-13-0153.1
    journal fristpage234
    journal lastpage241
    treeJournal of Applied Meteorology and Climatology:;2013:;volume( 053 ):;issue: 002
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian