YaBeSH Engineering and Technology Library

    • Journals
    • PaperQuest
    • YSE Standards
    • YaBeSH
    • Login
    View Item 
    •   YE&T Library
    • AMS
    • Journal of Applied Meteorology and Climatology
    • View Item
    •   YE&T Library
    • AMS
    • Journal of Applied Meteorology and Climatology
    • View Item
    • All Fields
    • Source Title
    • Year
    • Publisher
    • Title
    • Subject
    • Author
    • DOI
    • ISBN
    Advanced Search
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Archive

    Observing Local-Scale Variability of Near-Surface Temperature and Humidity Using a Wireless Sensor Network

    Source: Journal of Applied Meteorology and Climatology:;2011:;volume( 051 ):;issue: 001::page 30
    Author:
    Lengfeld, Katharina
    ,
    Ament, Felix
    DOI: 10.1175/JAMC-D-11-025.1
    Publisher: American Meteorological Society
    Abstract: n this paper the influence of surface type, wind speed, and other environmental conditions on near-surface air temperature, specific humidity, and surface temperature is studied. A wireless sensor network consisting of 13 low-cost meteorological stations was set up as a 2.3-km-long double transect in western Germany during the Fluxes and Patterns in the Soil?Vegetation?Atmosphere Scheme (FLUXPAT2009) campaign. This deployment covered various surface types, including a small river. It was found that the air temperature was mainly influenced by the distance to the river and that its variability is controlled by the wind speed. During the night, a pool of cold air formed in the valley close to the water. The specific humidity is also governed by proximity to the river, especially during the night and for low wind speeds. In contrast, the differences in surface temperature were caused by different land cover. These results can be confirmed by a cluster analysis. Setting up 13 stations in a relatively small area is not always feasible. In this study, an estimation of the error that is made by considering the effect of a reduced number of stations is given. Use of only a single station results in an error of 0.86 K in air temperature, 0.67 g kg?1 in specific humidity, and 1.4 K in surface temperature.
    • Download: (1.634Mb)
    • Show Full MetaData Hide Full MetaData
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      Observing Local-Scale Variability of Near-Surface Temperature and Humidity Using a Wireless Sensor Network

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4216873
    Collections
    • Journal of Applied Meteorology and Climatology

    Show full item record

    contributor authorLengfeld, Katharina
    contributor authorAment, Felix
    date accessioned2017-06-09T16:48:54Z
    date available2017-06-09T16:48:54Z
    date copyright2012/01/01
    date issued2011
    identifier issn1558-8424
    identifier otherams-74627.pdf
    identifier urihttp://onlinelibrary.yabesh.ir/handle/yetl/4216873
    description abstractn this paper the influence of surface type, wind speed, and other environmental conditions on near-surface air temperature, specific humidity, and surface temperature is studied. A wireless sensor network consisting of 13 low-cost meteorological stations was set up as a 2.3-km-long double transect in western Germany during the Fluxes and Patterns in the Soil?Vegetation?Atmosphere Scheme (FLUXPAT2009) campaign. This deployment covered various surface types, including a small river. It was found that the air temperature was mainly influenced by the distance to the river and that its variability is controlled by the wind speed. During the night, a pool of cold air formed in the valley close to the water. The specific humidity is also governed by proximity to the river, especially during the night and for low wind speeds. In contrast, the differences in surface temperature were caused by different land cover. These results can be confirmed by a cluster analysis. Setting up 13 stations in a relatively small area is not always feasible. In this study, an estimation of the error that is made by considering the effect of a reduced number of stations is given. Use of only a single station results in an error of 0.86 K in air temperature, 0.67 g kg?1 in specific humidity, and 1.4 K in surface temperature.
    publisherAmerican Meteorological Society
    titleObserving Local-Scale Variability of Near-Surface Temperature and Humidity Using a Wireless Sensor Network
    typeJournal Paper
    journal volume51
    journal issue1
    journal titleJournal of Applied Meteorology and Climatology
    identifier doi10.1175/JAMC-D-11-025.1
    journal fristpage30
    journal lastpage41
    treeJournal of Applied Meteorology and Climatology:;2011:;volume( 051 ):;issue: 001
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian