    Archive

    Urban Energy Fluxes in Built-Up Downtown Areas and Variations across the Urban Area, for Use in Dispersion Models

    Source: Journal of Applied Meteorology and Climatology:;2011:;volume( 050 ):;issue: 006::page 1341
    Author:
    Hanna, Steven
    ,
    Marciotto, Edson
    ,
    Britter, Rex
    DOI: 10.1175/2011JAMC2555.1
    Publisher: American Meteorological Society
    Abstract: urface energy fluxes, at averaging times from 10 min to 1 h, are needed as inputs to most state-of-the-art dispersion models. The sensible heat flux is a major priority, because it is combined with the momentum flux to estimate the stability, the wind profile, and the turbulence intensities. Because of recent concerns about dispersion in built-up downtown areas of large cities, there is a need to estimate sensible heat flux in the midst of tall buildings. In this paper, the authors work with some high-quality and relevant but arguably underutilized data. The results of analysis of urban heat flux components from 10 locations in suburban and built-up downtown areas in Oklahoma City, Oklahoma, during the Joint Urban 2003 (JU2003) field experiment are presented here. At street level in the downtown area, in the midst of tall skyscrapers, the ground heat flux and the sensible heat flux are relatively large and the latent heat flux is relatively small when compared with concurrent fluxes observed in the upwind suburban areas. In confirmation of measurements in other cities, the sensible heat flux in the downtown area is observed to be slightly positive (10?20 W m?2) at night, indicating nearly neutral or slightly unstable conditions. Also in agreement with observations in other cities is that the ground heat flux in the downtown area has a magnitude that is 3 or 4 times that in suburban or rural areas. These results should permit improved parameterizations of sensible heat fluxes in the urban downtown area with tall buildings.
    • Download: (1.649Mb)
    • Show Full MetaData Hide Full MetaData
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      Urban Energy Fluxes in Built-Up Downtown Areas and Variations across the Urban Area, for Use in Dispersion Models

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4213544
    Collections
    • Journal of Applied Meteorology and Climatology

    Show full item record

    contributor authorHanna, Steven
    contributor authorMarciotto, Edson
    contributor authorBritter, Rex
    date accessioned2017-06-09T16:39:14Z
    date available2017-06-09T16:39:14Z
    date copyright2011/06/01
    date issued2011
    identifier issn1558-8424
    identifier otherams-71631.pdf
    identifier urihttp://onlinelibrary.yabesh.ir/handle/yetl/4213544
    description abstracturface energy fluxes, at averaging times from 10 min to 1 h, are needed as inputs to most state-of-the-art dispersion models. The sensible heat flux is a major priority, because it is combined with the momentum flux to estimate the stability, the wind profile, and the turbulence intensities. Because of recent concerns about dispersion in built-up downtown areas of large cities, there is a need to estimate sensible heat flux in the midst of tall buildings. In this paper, the authors work with some high-quality and relevant but arguably underutilized data. The results of analysis of urban heat flux components from 10 locations in suburban and built-up downtown areas in Oklahoma City, Oklahoma, during the Joint Urban 2003 (JU2003) field experiment are presented here. At street level in the downtown area, in the midst of tall skyscrapers, the ground heat flux and the sensible heat flux are relatively large and the latent heat flux is relatively small when compared with concurrent fluxes observed in the upwind suburban areas. In confirmation of measurements in other cities, the sensible heat flux in the downtown area is observed to be slightly positive (10?20 W m?2) at night, indicating nearly neutral or slightly unstable conditions. Also in agreement with observations in other cities is that the ground heat flux in the downtown area has a magnitude that is 3 or 4 times that in suburban or rural areas. These results should permit improved parameterizations of sensible heat fluxes in the urban downtown area with tall buildings.
    publisherAmerican Meteorological Society
    titleUrban Energy Fluxes in Built-Up Downtown Areas and Variations across the Urban Area, for Use in Dispersion Models
    typeJournal Paper
    journal volume50
    journal issue6
    journal titleJournal of Applied Meteorology and Climatology
    identifier doi10.1175/2011JAMC2555.1
    journal fristpage1341
    journal lastpage1353
    treeJournal of Applied Meteorology and Climatology:;2011:;volume( 050 ):;issue: 006
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian