contributor author | Aceves-Navarro, L. A. | |
contributor author | Hubbard, K. O. | |
contributor author | Schmidt, J. | |
date accessioned | 2017-06-09T15:24:18Z | |
date available | 2017-06-09T15:24:18Z | |
date copyright | 1988/12/01 | |
date issued | 1988 | |
identifier issn | 0739-0572 | |
identifier other | ams-428.pdf | |
identifier uri | http://onlinelibrary.yabesh.ir/handle/yetl/4181511 | |
description abstract | Techniques for simultaneously calibrating a number of pyranometers for use with automated weather stations are examined. The pressure involves taking data from an Eppley precision spectral pyranometer and from up to 11 LI-COR pyranometers using a specially built sensor plate. Results of a group calibration of six pyranometers using 10-minute data over a 3-day period are given. Three best-fit lines were determined for full-scale (5?960 W m?2), midscale (300?650 W m?2) and midrank (400?800 W m?2) datasets. The full-scale calibration technique proved most useful, resulting in a standard error of estimate of less than 20 W m?2 in all cases. | |
publisher | American Meteorological Society | |
title | Group Calibration of Silicon Cell Pyranometers for Use in an Automated Network | |
type | Journal Paper | |
journal volume | 5 | |
journal issue | 6 | |
journal title | Journal of Atmospheric and Oceanic Technology | |
identifier doi | 10.1175/1520-0426(1988)005<0875:GCOSCP>2.0.CO;2 | |
journal fristpage | 875 | |
journal lastpage | 879 | |
tree | Journal of Atmospheric and Oceanic Technology:;1988:;volume( 005 ):;issue: 006 | |
contenttype | Fulltext | |