contributor authorAceves-Navarro, L. A.
contributor authorHubbard, K. O.
contributor authorSchmidt, J.
date accessioned2017-06-09T15:24:18Z
date available2017-06-09T15:24:18Z
date copyright1988/12/01
date issued1988
identifier issn0739-0572
identifier otherams-428.pdf
identifier urihttp://onlinelibrary.yabesh.ir/handle/yetl/4181511
description abstractTechniques for simultaneously calibrating a number of pyranometers for use with automated weather stations are examined. The pressure involves taking data from an Eppley precision spectral pyranometer and from up to 11 LI-COR pyranometers using a specially built sensor plate. Results of a group calibration of six pyranometers using 10-minute data over a 3-day period are given. Three best-fit lines were determined for full-scale (5?960 W m?2), midscale (300?650 W m?2) and midrank (400?800 W m?2) datasets. The full-scale calibration technique proved most useful, resulting in a standard error of estimate of less than 20 W m?2 in all cases.
publisherAmerican Meteorological Society
titleGroup Calibration of Silicon Cell Pyranometers for Use in an Automated Network
typeJournal Paper
journal volume5
journal issue6
journal titleJournal of Atmospheric and Oceanic Technology
identifier doi10.1175/1520-0426(1988)005<0875:GCOSCP>2.0.CO;2
journal fristpage875
journal lastpage879
treeJournal of Atmospheric and Oceanic Technology:;1988:;volume( 005 ):;issue: 006