| contributor author | Richard R. Noss | |
| contributor author | Gregory J. Newman | |
| contributor author | James W. Male | |
| date accessioned | 2017-05-08T21:06:16Z | |
| date available | 2017-05-08T21:06:16Z | |
| date copyright | January 1987 | |
| date issued | 1987 | |
| identifier other | %28asce%290733-9496%281987%29113%3A1%281%29.pdf | |
| identifier uri | http://yetl.yabesh.ir/yetl/handle/yetl/38803 | |
| description abstract | A procedure is developed to determine the optimal testing frequency for 5/8‐in. meters. The objective is to minimize the cost to the utility, including the cost of the meter testing program itself and the cost (revenue loss) of the water not registered due to meter inaccuracy. Water losses due to both working, but inaccurate, meters and failed meters are accounted for. The rate of decline of meter accuracy with age was found to be the most significant influence on the optimal testing frequency. | |
| publisher | American Society of Civil Engineers | |
| title | Optimal Testing Frequency for Domestic Water Meters | |
| type | Journal Paper | |
| journal volume | 113 | |
| journal issue | 1 | |
| journal title | Journal of Water Resources Planning and Management | |
| identifier doi | 10.1061/(ASCE)0733-9496(1987)113:1(1) | |
| tree | Journal of Water Resources Planning and Management:;1987:;Volume ( 113 ):;issue: 001 | |
| contenttype | Fulltext | |