Show simple item record

contributor authorRichard R. Noss
contributor authorGregory J. Newman
contributor authorJames W. Male
date accessioned2017-05-08T21:06:16Z
date available2017-05-08T21:06:16Z
date copyrightJanuary 1987
date issued1987
identifier other%28asce%290733-9496%281987%29113%3A1%281%29.pdf
identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/38803
description abstractA procedure is developed to determine the optimal testing frequency for 5/8‐in. meters. The objective is to minimize the cost to the utility, including the cost of the meter testing program itself and the cost (revenue loss) of the water not registered due to meter inaccuracy. Water losses due to both working, but inaccurate, meters and failed meters are accounted for. The rate of decline of meter accuracy with age was found to be the most significant influence on the optimal testing frequency.
publisherAmerican Society of Civil Engineers
titleOptimal Testing Frequency for Domestic Water Meters
typeJournal Paper
journal volume113
journal issue1
journal titleJournal of Water Resources Planning and Management
identifier doi10.1061/(ASCE)0733-9496(1987)113:1(1)
treeJournal of Water Resources Planning and Management:;1987:;Volume ( 113 ):;issue: 001
contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record