    Archive

    Measurement of Two-Dimensional Periodic Flow With a Cobra Probe

    Source: Journal of Fluids Engineering:;1973:;volume( 095 ):;issue: 002::page 295
    Author:
    Y. Senoo
    ,
    Y. Kita
    ,
    K. Ookuma
    DOI: 10.1115/1.3447020
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: Three semiconductor pressure transducers were inserted into a cobra probe to measure instantaneous condition of flow at the exit of a pump impeller. As it was difficult to calibrate a probe in a two-dimensional periodic flow which was similar to the periodic flow to be measured, the authors used the probe assuming that the steady flow characteristics were valid and examined the results in several ways. The results at different pump speeds satisfied the similarity law of flow from the impeller, and it was concluded that the time response of the probe and pressure transducer system was satisfactory. Almost identical results were obtained regardless of the orientation of the probe, and it was concluded that the calibration curve at steady state was applicable to the unsteady state. Finally, the static pressure calculated from the probe output agreed with the wall pressure which was directly measured with a semiconductor pressure transducer. The authors believe that the three steps are sufficient to prove that the results obtained with the probe are reliable and the probe system is suitable for measurement of periodic flow at the exit of impeller of a pump.
    keyword(s): Flow (Dynamics) , Probes , Pressure transducers , Impellers , Pumps , Semiconductors (Materials) , Pressure , Steady state , Pump impellers AND Calibration ,
    • Download: (439.6Kb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      Measurement of Two-Dimensional Periodic Flow With a Cobra Probe

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/163922
    Collections
    • Journal of Fluids Engineering

    Show full item record

    contributor authorY. Senoo
    contributor authorY. Kita
    contributor authorK. Ookuma
    date accessioned2017-05-09T01:36:38Z
    date available2017-05-09T01:36:38Z
    date copyrightJune, 1973
    date issued1973
    identifier issn0098-2202
    identifier otherJFEGA4-26845#295_1.pdf
    identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/163922
    description abstractThree semiconductor pressure transducers were inserted into a cobra probe to measure instantaneous condition of flow at the exit of a pump impeller. As it was difficult to calibrate a probe in a two-dimensional periodic flow which was similar to the periodic flow to be measured, the authors used the probe assuming that the steady flow characteristics were valid and examined the results in several ways. The results at different pump speeds satisfied the similarity law of flow from the impeller, and it was concluded that the time response of the probe and pressure transducer system was satisfactory. Almost identical results were obtained regardless of the orientation of the probe, and it was concluded that the calibration curve at steady state was applicable to the unsteady state. Finally, the static pressure calculated from the probe output agreed with the wall pressure which was directly measured with a semiconductor pressure transducer. The authors believe that the three steps are sufficient to prove that the results obtained with the probe are reliable and the probe system is suitable for measurement of periodic flow at the exit of impeller of a pump.
    publisherThe American Society of Mechanical Engineers (ASME)
    titleMeasurement of Two-Dimensional Periodic Flow With a Cobra Probe
    typeJournal Paper
    journal volume95
    journal issue2
    journal titleJournal of Fluids Engineering
    identifier doi10.1115/1.3447020
    journal fristpage295
    journal lastpage299
    identifier eissn1528-901X
    keywordsFlow (Dynamics)
    keywordsProbes
    keywordsPressure transducers
    keywordsImpellers
    keywordsPumps
    keywordsSemiconductors (Materials)
    keywordsPressure
    keywordsSteady state
    keywordsPump impellers AND Calibration
    treeJournal of Fluids Engineering:;1973:;volume( 095 ):;issue: 002
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian