    Solid Oxide Cell Microstructural Performance in Hydrogen and Carbon Monoxide Reactant Streams

    Source: Journal of Electrochemical Energy Conversion and Storage:;2016:;volume( 013 ):;issue: 001::page 11009
    Author:
    van Zandt, Zachary K.
    ,
    Nelson, George J.
    DOI: 10.1115/1.4034114
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: A distributed charge transfer (DCT) model has been developed to analyze solid oxide fuel cells (SOFCs) and electrolyzers operating in H2–H2O and CO–CO2 atmospheres. The model couples mass transport based on the dustygas model (DGM), ion and electron transport in terms of charged species electrochemical potentials, and electrochemical reactions defined by Butler–Volmer kinetics. The model is validated by comparison to published experimental data, particularly cell polarization curves for both fuel cell and electrolyzer operation. Parametric studies have been performed to compare the effects of microstructure on the performance of SOFCs and solid oxide electrolysis cells (SOECs) operating in H2–H2O and CO–CO2 gas streams. Compared to the H2–H2O system, the power density of the CO–CO2 system shows a greater sensitivity to pore microstructure, characterized by the porosity and tortuosity. Analysis of the pore diameter concurs with the porosity and tortuosity parametric studies that CO–CO2 systems are more sensitive to microstructural changes than H2–H2O systems. However, the concentration losses of the CO–CO2 system are significantly higher than those of the H2–H2O system for the pore sizes analyzed. While both systems can be shown to improve in performance with higher porosity, lower tortuosity, and larger pore sizes, the results of these parametric studies imply that CO–CO2 systems would benefit more from such microstructural changes. These results further suggest that objectives for tailoring microstructure in solid oxide cells (SOCs) operating in CO–CO2 are distinct from objectives for more common H2focused systems.
    • Download: (1.249Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      Solid Oxide Cell Microstructural Performance in Hydrogen and Carbon Monoxide Reactant Streams

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/160786
    Collections
    • Journal of Electrochemical Energy Conversion and Storage

    Show full item record

    contributor authorvan Zandt, Zachary K.
    contributor authorNelson, George J.
    date accessioned2017-05-09T01:27:23Z
    date available2017-05-09T01:27:23Z
    date issued2016
    identifier issn2381-6872
    identifier otherjeecs_013_01_011009.pdf
    identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/160786
    description abstractA distributed charge transfer (DCT) model has been developed to analyze solid oxide fuel cells (SOFCs) and electrolyzers operating in H2–H2O and CO–CO2 atmospheres. The model couples mass transport based on the dustygas model (DGM), ion and electron transport in terms of charged species electrochemical potentials, and electrochemical reactions defined by Butler–Volmer kinetics. The model is validated by comparison to published experimental data, particularly cell polarization curves for both fuel cell and electrolyzer operation. Parametric studies have been performed to compare the effects of microstructure on the performance of SOFCs and solid oxide electrolysis cells (SOECs) operating in H2–H2O and CO–CO2 gas streams. Compared to the H2–H2O system, the power density of the CO–CO2 system shows a greater sensitivity to pore microstructure, characterized by the porosity and tortuosity. Analysis of the pore diameter concurs with the porosity and tortuosity parametric studies that CO–CO2 systems are more sensitive to microstructural changes than H2–H2O systems. However, the concentration losses of the CO–CO2 system are significantly higher than those of the H2–H2O system for the pore sizes analyzed. While both systems can be shown to improve in performance with higher porosity, lower tortuosity, and larger pore sizes, the results of these parametric studies imply that CO–CO2 systems would benefit more from such microstructural changes. These results further suggest that objectives for tailoring microstructure in solid oxide cells (SOCs) operating in CO–CO2 are distinct from objectives for more common H2focused systems.
    publisherThe American Society of Mechanical Engineers (ASME)
    titleSolid Oxide Cell Microstructural Performance in Hydrogen and Carbon Monoxide Reactant Streams
    typeJournal Paper
    journal volume13
    journal issue1
    journal titleJournal of Electrochemical Energy Conversion and Storage
    identifier doi10.1115/1.4034114
    journal fristpage11009
    journal lastpage11009
    identifier eissn2381-6910
    treeJournal of Electrochemical Energy Conversion and Storage:;2016:;volume( 013 ):;issue: 001
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian