Show simple item record

contributor authorAgarwal, Aakas
contributor authorIngels, Marcel
contributor authorKodigudla, Manoj
contributor authorMomeni, Narjes
contributor authorGoel, Vijay
contributor authorAgarwal, Anand K.
date accessioned2017-05-09T01:26:09Z
date available2017-05-09T01:26:09Z
date issued2016
identifier issn0148-0731
identifier otherbio_138_05_051004.pdf
identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/160402
description abstractAdjacentlevel disease is a common iatrogenic complication seen among patients undergoing spinal fusion for low back pain. This is attributed to the postsurgical differences in stiffness between the spinal levels, which result in abnormal forces, stress shielding, and hypermobility at the adjacent levels. In addition, as most patients undergoing these surgeries are osteoporotic, screw loosening at the index level is a complication that commonly accompanies adjacentlevel disease. Recent studies indicate that a rod with lower rigidity than that of titanium may help to overcome these detrimental effects at the adjacent level. The present study was conducted in vitro using 12 L1S1 specimens divided into groups of six, with each group instrumented with either titanium rods or PEEK (polyetheretherketone) rods. The test protocol included subjecting intact specimens to pure moments of 10 Nm in extension and flexion using an FS20 Biomechanical Spine Test System (Applied Test Systems) followed by hybrid moments on the instrumented specimens to achieve the same L1S1 motion as that of the intact specimens. During the protocol's later phase, the L4L5 units from each specimen were segmented for cyclic loading followed by postfatigue kinematic analysis to highlight the differences in motion preand postfatigue. The objectives included the in vitro comparison of (1) the adjacentlevel motion before and after instrumentation with PEEK and titanium rods and (2) the preand postfatigue motion at the instrumented level with PEEK and titanium rods. The results showed that the adjacent levels above the instrumentation caused increased flexion and extension with both PEEK and titanium rods. The postfatigue kinematic data showed that the motion at the instrumented level (L4L5) increased significantly in both flexion and extension compared to prefatigue motion in titanium groups. However, there was no significant difference in motion between the preand postfatigue data in the PEEK group.
publisherThe American Society of Mechanical Engineers (ASME)
titleAdjacent Level Hypermobility and Instrumented Level Fatigue Loosening With Titanium and PEEK Rods for a Pedicle Screw System: An In Vitro Study
typeJournal Paper
journal volume138
journal issue5
journal titleJournal of Biomechanical Engineering
identifier doi10.1115/1.4032965
journal fristpage51004
journal lastpage51004
identifier eissn1528-8951
treeJournal of Biomechanical Engineering:;2016:;volume( 138 ):;issue: 005
contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record