Show simple item record

contributor authorMayo, Ignacio
contributor authorArts, Tony
contributor authorEl
contributor authorParres, Benjamin
date accessioned2017-05-09T01:24:24Z
date available2017-05-09T01:24:24Z
date issued2015
identifier issn0889-504X
identifier otherturbo_137_03_031002.pdf
identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/159890
description abstractThe convective heat transfer distribution in a ribroughened rotating internal cooling channel was measured for different rotation and Reynolds numbers, representative of engine operating conditions. The test section consisted of a channel of aspect ratio equal to 0.9 with one wall equipped with eight ribs perpendicular to the main flow direction. The pitch to rib height ratio was 10 and the rib blockage was 10%. The test rig was designed to provide a uniform heat flux boundary condition over the ribbed wall, minimizing the heat transfer losses and allowing temperature measurements at significant rotation rates. Steadystate liquid crystal thermography (LCT) was employed to quantify a detailed 2D distribution of the wall temperature, allowing the determination of the convective heat transfer coefficient along the area between the sixth and eighth rib. The channel and all the required instrumentation were mounted on a large rotating disk, providing the same spatial resolution and measurement accuracy as in a stationary rig. The assembly was able to rotate both in clockwise and counterclockwise directions, so that the investigated wall was acting either as leading or trailing side, respectively. The tested Reynolds number values (based on the hydraulic diameter of the channel) were 15,000, 20,000, 30,000, and 40,000. The maximum rotation number values were ranging between 0.12 (Re = 40,000) and 0.30 (Re = 15,000). Turbulence profiles and secondary flows modified by rotation have shown their impact not only on the average value of the heat transfer coefficient but also on its distribution. On the trailing side, the heat transfer distribution flattens as the rotation number increases, while its averaged value increases due to the turbulence enhancement and secondary flows induced by the rotation. On the leading side, the secondary flows counteract the turbulence reduction and the overall heat transfer coefficient exhibits a limited decrease. In the latter case, the secondary flows are responsible for high heat transfer gradients on the investigated area.
publisherThe American Society of Mechanical Engineers (ASME)
titleTwo Dimensional Heat Transfer Distribution of a Rotating Ribbed Channel at Different Reynolds Numbers
typeJournal Paper
journal volume137
journal issue3
journal titleJournal of Turbomachinery
identifier doi10.1115/1.4028458
journal fristpage31002
journal lastpage31002
identifier eissn1528-8900
treeJournal of Turbomachinery:;2015:;volume( 137 ):;issue: 003
contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record